按照冷却器的设计参数,对冷却器的管箱、管束进行材料、结构的选择。根据相关标准的规定,对换热器进行计算校核。
The material and structure of channel and pipe bundle were analyzed according to the design data. Calculation and analyzing of cooler were finished based on interrelated standards.