期刊文献+

南水北调京石段供水水源与北京自产水源水质差异性分析

原文传递
导出
摘要 对比分析了南水北调京石段应急供水河北4库和北京唯一的地表水源地密云水库的水质差异。研究表明,5座水库中以密云水库水质最好。黄壁庄水库因硫酸盐超标、矿化度和硬度较高、营养盐成分较高、水化学类型与密云水库差异较大及对供水管网腐蚀能力较强等原因,不宜单独作为北京的调水水源。其余3库水质虽然劣于密云水库,但总体上满足饮用水源地II类水质标准,总硬度和矿化度适中,和密云水库水化学特征相近,供水时不会对北京现有供水管网造成明显冲击。岗南水库处于富营养化状态,应注意防范夏秋季节的水华问题。
作者 赵红磊
出处 《北京水务》 2012年第4期7-10,共4页 Beijing Water
  • 相关文献

参考文献3

  • 1地表水资源质量评价技术规程[M].中华人民共和国水利部,2007.7-9.
  • 2Larson T mains [J]. E.Report on loss in carrying capacity of water Journal of American Water Works Association, 1995, 45: 1061-1071.
  • 3王洋,张晓健,陈超,潘安君,徐扬,廖平安,张素霞,顾军农.水源切换引起给水管网黄水问题原因分析[J].环境科学,2009,30(12):3555-3561. 被引量:60

二级参考文献17

  • 1牛璋彬,王洋,张晓健,何文杰,韩宏大,阴沛军.给水管网中管内壁腐蚀管垢特征分析[J].环境科学,2006,27(6):1150-1154. 被引量:27
  • 2国家环保总局.水与废水监测分析方法[M].(第四版).北京:中国环境科学出版社,2006.221-237.
  • 3Antunes R A, Costa I, Faria D L A. Characterization of corrosion products formed on steels in the first months of atmospheric exposure [J]. Materia,2003,8(1) :27-34.
  • 4Sarin P, Snoyink V L, Lytle D A, et al. Iron corrosion scales: model for scale growth, iron release, and colored water formation[ J ]. Journal of Environmental Engineering, 2004,4 : 364-373.
  • 5Snoeyink V L, Ferguson J F, Ryder R, et al. Internal corrosion of water distribution systems [ R ]. USA : AWWA Research Foundation, 1985. 79-87.
  • 6Sarin P. Iron release from corrosion scales in old iron/steel drinking water distribution pipes[ D ]. USA : University of Illinois, 2001. 122- 134.
  • 7Lytle D A,Magnuson M L, Snoeyink V L. Effect of oxidants on the properties of Fe (Ⅲ) particles and suspensions formed from the oxidation of Fe( Ⅱ ) [J]. Journal of AWWA,2004,96(8) : 112-126.
  • 8Satin P,Snoyink V L,Bebee J, et al. Iron release from corroded iron pipes in drinking water distribution systems:effect of dissolved oxygen [J]. Water Research,2004,38: 1259-1269.
  • 9Lytle D A, Sarin P, Snoyink V L. The effect of chloride and orthophosphate on the release of iron from a cast iron pipe section[ J]. Journal of Water Supply : Research and Technology, 2005,54(5) : 267- 281.
  • 10Sander A, Berghult B, Broo A E, et al. Iron corrosion in drinking water distribution systems: the effect of pH, calcium and hydrogen carbonate[J]. Corrosion Science, 1996,38(3) :443-455.

共引文献60