摘要
针对湿法脱硫浆液循环泵减速机主动轴断裂的故障,从减速机外观运行状况、工况系数及扭转强度等方面分析确定原因,提出解决措施。
Aiming at active axes rupture failure of wet FGD slurry circulating pump, analyzes and confirms the causes from the aspects of appearance, gear operation condition, condition coefficient and torsion strength, and puts forwards the measures.
出处
《河北电力技术》
2012年第B07期38-40,共3页
Hebei Electric Power
关键词
湿法脱硫浆液循环泵
减速机
工况系数
扭转强度
wet FGD frequent slurry circulating pump
gear
condition coefficient
torsion strength