期刊文献+

HPLC法测定美洛昔康口腔崩解片中美洛昔康的含量 被引量:1

Determination of meloxicam orally disintegrating tablets by HPLC
下载PDF
导出
摘要 目的:建立HPLC法测定美洛昔康口腔崩解片中美洛昔康的含量。方法:采用C18色谱柱(250 mm×4.6mm,5μm),流动相为甲醇-0.1 moL/L乙酸铵溶液(60∶40),用15%高氯酸调节pH至(6.0±0.1),流速为1.0 ml/min,检测波长为271 nm,进样量20μl,柱温:室温。结果:美洛昔康在40~60μg/ml的浓度范围内,峰面积与浓度的线性关系良好(r=0.999 8),平均回收率为100.46%,RSD为0.54%。结论:该方法快速、简单、准确、重复性好。 Objective:To establish a HPLC method for the determination of rneloxicam orally disintegrating tablets. Method:The ClS Column(250 mm×4.6 ram,5 μm) was used,the mobile phase was methanol - 0.1 moI./L ammonium acetate(60: 40) ,and adjust with 15% perchloric acid to a pH of (6.0 ±0.1). The flow rate was 1.0 ml/min,the detection wavelength waft 271 nm,the temperature of column was room temperature. Result: The linear rang of rneloxicam was 40 ~ 60 μg/ml( r = 0.999 8 ), the average recovery was 100.46% ,with RSD was 0.54%. Conclusion: The method is rapid, simple, accurate and good reproducibility.
出处 《天津药学》 2012年第4期10-11,共2页 Tianjin Pharmacy
关键词 美洛昔康 口腔崩解片 高效液相色谱法 含量测定 meloxicam, orally disintegrating tablets, HPLC, content