期刊文献+

上海光源XBPM自动量程I-V转换器的研制

A Automatic-ranging I/V Convertor Design for X-ray Beam Position Monitor of SSRF
下载PDF
导出
摘要 上海光源XBPM自动量程I/V转换器主要用于光束线的刀片式探测器和丝扫描探测器的信号读出,所需测量的电流动态范围大,从pA到mA量级的跨度;工作环境中有较多驱动电机的信号干扰,需要进行抗干扰和低噪声设计,以提高设备的信噪比,保证测量数据的精度和稳定度。论文给出了电路和相关程序设计,以及自动量程I/V转换器的测试结果。 The automatic-ranging current voltage convertor mainly aims for reading out the photocurrent largely ranging from pA to mA that comes from the blade or wire scanning detectors used in the synchrotron beamline.Anti-jamming design and low noise design are needed to increase the instrument’s SNR and guarantee the precision and stability of the measure data because of the electromagnetic interference from all kinds of working motors.The design of circuit and program and the related test result are given in the paper.
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2012年第6期686-689,714,共5页 Nuclear Electronics & Detection Technology
关键词 X射线光束位置探测器 放大器 单片机 自动量程 XBPM amplifier microcontroller automatic-ranging
  • 相关文献

参考文献6

  • 1华冬,余笑寒,黎忠,徐洪杰.上海光源光束位置探测系统的标定[J].核技术,2009,32(9):641-644. 被引量:2
  • 2http ://www. analog. com/static/imported - files/data_sheets/ADS49. pdf.
  • 3http ://www. analog, corn/static/imported - files/data_sheets/AD7328. pdf.
  • 4http://www. nxp. com/documents/data- sheet/P89V51RB2_RC2_RD2. pdf.
  • 5朱善君.单片机接口技术及应用[M].北京:清华大学出版社,2005.
  • 6http://www. ahera. com. cn/literature/ds/m7000. pdf.