基于光电容积脉搏波描记法的无创连续血压测量 被引量:53

The Research Progress of Non-Invasive and Continuous Blood Pressure Measurement Based on Photoplethysmography
下载PDF
导出
摘要 为了摆脱传统血压计充气袖带的束缚、实现长期连续的血压监测,很多学者开展了基于PPG实现无创、连续血压监测的研究。阐述基于光电容积脉搏波描记法(PPG)实现无创、连续血压测量的基本原理。将当前基于PPG无创血压监测的研究分为3类,分别为心电(ECG)与PPG结合的血压测量技术、两路PPG结合的血压测量技术、脉搏波特征参数血压测量技术,分析这3类技术的基本测量原理、测量精度及其优缺点。在此基础上,论述基于PPG实现无创、连续监测血压的发展方向。 Noninvasive and continuous blood pressure monitoring have been intensively investigated and developed in attempt to getting rid of inflatable cuff and realizing the long term blood pressure monitoring. This article analyzed the principle of noninvasive and continuous blood pressure measurement based on photoplethysmography (PPG). The researches of current noninvasive blood pressure monitoring based on the PPG ware claasi fled into three categories including combination of electrocardiograph (ECG) and PPG, two channels PPG, and utilization of pulse characteristic parameter. The measurement accuracy, advantage and disadvantage of the three technologies were summarized. The development tendency of the noninvasive and continuous monitoring blood pressure based on the PPG was discussed.
出处 《中国生物医学工程学报》 CAS CSCD 北大核心 2012年第4期607-614,共8页 Chinese Journal of Biomedical Engineering
基金 上海市科委2011年度"科技创新行动计划"生物医药领域产学研医合作项目(11DZ1921703)
关键词 血压 光电容积脉搏波描记法 无创 blood pressure photoplethysmography (PPG) noninvasive
  • 相关文献

参考文献34

  • 1Dai X, Diamond JA. Intraeerebral hemorrhage: a life-threatening eomplieatlon of hypertension during pregnancy [ J ]. J Clin Hypertens( Greenwich), 2007, 9 ( 11 ) : 897 - 900.
  • 2焦学军,房兴业.连续每搏血压测量方法的研究进展[J].航天医学与医学工程,2000,13(2):148-151. 被引量:21
  • 3滕晓菲,张元亭.移动医疗:穿戴式医疗仪器的发展趋势[J].中国医疗器械杂志,2006,30(5):330-340. 被引量:84
  • 4Kikuya M, Hozawa A, Ohokubo T, et al. Prognostic significance of blood pressure and heart rate variabilitier: the ohasama study [ J]. Hypertension, 2000, 36(5 ) : 901 - 905.
  • 5Rhee S, Yang BH, Asada HH. Artifact-resistant, power-efficient design of finger-ring plethysmographic sensors. I. Design and analysis [ C ]// 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Chicago: IEEE, 2000 : 2792 - 2795.
  • 6Nichols WW, Rourkc MFO. McDonald' s Blood Flow in Arteries Theoretical, experimental, and clinical principles [ M ]. (4th edition). London: Hodder Arnold Publication, 1998: 16- 18.
  • 7Hughes DJ, Bahbs CF, Gedes LA, et al. Measurements of Young' s modulus of elasticity of the canine aorta with ultrasound [J]. Ultrasonic Imaging, 1979, 1(4) : 356 -367.
  • 8Nitzan M, Khanokh B, Slovik Y. The difference in pulse transit time to the toe and finger measured by photoplethysmography [J]. Physiol Meas, 2002, 23(1): 85-93.
  • 9Lehmann ED, Hopkins KD and Gosling R. Aortic compliance measurements using Doppler ultrasound: in vivo biochemical correlates [J]. Ultrasound Med Biol, 1993, 19(9) : 683 -710.
  • 10Spulak D, Cmejla R, Fabian pressure estimation based photoplethysmography [ C ]// V. Parameters for mean blood on electrocardiography and International Conference On Applied Electronics. Pilsen: IEEE, 2011 : 1 -4.

二级参考文献93

共引文献121

同被引文献416

引证文献53

二级引证文献171

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部