阐述了刘家峡水电厂1号机转轮更换前后机组的稳定运行情况,介绍了1号机原转轮叶片裂纹情况、补焊修复措施,并根据转轮更换前后机组稳定性试验数据,分析了机组在不同负荷区域的稳定性能。
Stability of Unit 1 runner before and after being replaced, Liujiaxia Hydropower Plant is described. Cracks and their welding repair of the original Unit 1 runner blades are introduced. Furthermore, stability performances of units at different loads are analyzed according to test data on stability of units with the runner before and after being replaced.