期刊文献+

蛇形流道太阳能平板空气集热器集热性能研究 被引量:13

STUDY ON A FLAT PLATE SOLAR AIR COLLECTOR WITH SERPENTINE FLOW PASSAGES
下载PDF
导出
摘要 对一种蛇形流道太阳能平板空气集热器的集热性能进行研究,揭示流道转弯数N与蛇形流道集热器集热性能之间的关系,得到集热器流道转弯数的推荐值。指出大转弯数蛇形流道空气集热器FR值可近似用N=1时的FR值进行替代研究,当N>5时,集热器热迁移因子FR与N=1误差不超过5%。通过理论研究,获得带金属隔板蛇形流道集热器热迁移因子FR的理论表达式,并对集热器进行优化,使集热器热迁移因子FR提高到0.81。 A flat plate solar air collector with serpentine flow passages was studied. The relationships between the efficiency factor, the heat-removal factor of the solar air collector and the turning numbers, and found the recom- mended values. The article also pointed out that the heat removal factor FR of large turning number air collector can be instead by N = 1 approximately. When N 〉 5, the error of collector heat removal factor FR are less than 5%, compared with N = 1. The theoretical formula of the collector's thermal efficiency is obtained, which can be used for design and application of such kind of collectors.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2012年第9期1560-1564,共5页 Acta Energiae Solaris Sinica
基金 "十一五"国家科技支撑计划(2008BAJ12B01)
关键词 空气集热器 效率因子 热迁移因子 蛇形流道 solar air collector efficiency factor heat-removal factor serpentine flow passages
  • 相关文献

参考文献13

  • 1Yeh Ho-Ming, Ho Chii-Dong. Effect of external recycle on the performances of flat-plate solar air heaters with in- ternal fins attached [ J]. Renewable Energy, 2009, 34 (9) : 1340-1347.
  • 2Abdel S l-Khalik. Heat removal factor for a flat plate solar collector with a serpentine tube[ J]. Solar Energy, 1976, 18( 1 ) : 59-61.
  • 3Zhang Hefei, Lavan Z. Thermal performance of a serpen- tine absorber plate [ J ]. Solar Energy, 1985, 34 (2) : 471 -476.
  • 4张鹤飞,卓尔曼·拉尼.带蛇形管吸热板的热性能[J].太阳能学报,1985,6(2):115-123.
  • 5张鹤飞.F^R的通用无因次曲线[J].自然杂志,1987,10(8):631-631.
  • 6Klein S A. Calculation of flat-plate loss coefficients [J]. Solar Energy, 1975, 17(1) : 79-80.
  • 7侯宏娟,王志峰,王如竹,祁冰.平板型太阳集热器热性能的快速测试方法研究[J].太阳能学报,2004,25(3):310-314. 被引量:5
  • 8McAdams W H. Heat transmission ( 5rd edit) [ J ]. New York: McGraw-Hill, 1954.
  • 9Hottel H C, Woertz B B. Performance of fiat-plate solar- heat collector [ J ]. Transactions of the ASME, 1942, 64 ( 1 ) : 91-104.
  • 10Gao W, Lin W, Liu T, et al. Analytical and experimental studies on the thermal performance of cross-corrugated and flat-plate solar air heaters [ J ]. Applied Energy, 2007, 84(4) : 425-441.

二级参考文献15

  • 1Amer E H, et al. Comparison of two dynamic test methods for solar flat-plate collectors [J]. Energy Convers Mgmt, 1998, 39: 285-293.
  • 2Nayak J K, et al. Experimental and theoretical evaluation of dynamic test procedures for solar flat-plate collectors [J]. Solar Energy, 2000, 69: 337-401.
  • 3Perers B. Dynamic method for solar collector array testing and evaluation with standard database and simulation programs [J]. Solar Energy, 1993, 50: 517-526.
  • 4Amer E H , et al. Transient method for testing flatplate solar collectors [ J ]. Energy Convers. Mgmt ,1998, 39: 549-558.
  • 5Amer E H , et al. A new dynamic method for testing solar flat-plate collectors under variable weather [J].Energy Conversion & Management, 1999, 40: 803-823.
  • 6Muschaweck J, Spirkl W. Dynamic solar collector performance testing [J]. Solar Energy Materials and Solar Cells, 1993, 30: 95-105.
  • 7Emery M, Rogers B A. On a solar collector thermal performance test method for use in variable conditions [J]. Solar Energy, 1984, 33: 117-123.
  • 8BS 6757, British Standard Method of Test for Thermal Performance of Solar Collectors[ S].
  • 9Wang X A, Xu Y F, Meng X Y. A filter method for transient testing of collectors performance [J].Solar Energy, 1987, 38: 125-134.
  • 10Amer E H, et al. Evaluation of a transient test procedure for solar flat - plate collectors[J]. Energy, 1999,24: 979-995.

共引文献36

同被引文献99

引证文献13

二级引证文献39

相关作者