摘要
该文以武港集箱阳逻新港办公楼的设计为例,摒弃传统外墙节能的思路,首先在设计过程中提出了主动式系统化节能的新理念,并付诸实施。运用Ecotect Analysis软件进行了深入分析与比较,直观地验证了主动式系统化建筑节能理念在武汉地区的合理性及优越性。
This paper,taking the Wuhan Yangluo new port transportation company office building design as an example,abandons the traditional external energy-saving ideas in the design process,puts forward active system energy-saving first of all,and puts these new ideas into practice.In this article,we use Ecotect Analysis software to analyze and compare,visually verify the rationality and superiority of the active system of energy-saving building concept in Wuhan region.
出处
《华中建筑》
2012年第10期54-57,共4页
Huazhong Architecture