摘要
详细介绍了东方锅炉为越南海防项目提供的新型300 MW"W"型火焰锅炉经现场调试后的基本性能和NOx的变化规律,总结出乏气风、二次风各档板以及总风量等锅炉运行参数对锅炉性能及污染物排放的影响,为后续300 MW"W"型火焰锅炉的进一步优化及开发更大容量、更加环保的"W"型火焰锅炉提供了很有价值的经验。
The basic performance and NO, changing law of DBC' s new type 300 MW "W" boiler for Vietnam Haifang project are presented and the effects of such operation parameters as exhaust air, secondary air dampers and total air amount, etc. on the boiler performance and pollutant emission are summarized, thus providing valuable experiences for further optimizing 300 MW "W" type boiler and developing more environmental "W" type boiler with larger capacity.
出处
《东方电气评论》
2012年第3期16-25,共10页
Dongfang Electric Review