期刊文献+

严寒地区工业给排水设计要点 被引量:2

Industrial Water Supply and Drainage Design Points in Severe Cold Region
下载PDF
导出
摘要 针对北方严寒地区冬季气温低的特点,工业企业给排水系统的设计应采用安全可靠、经济合理的技术措施,以解决管道及设备的保温防冻问题,确保工业企业的正常生产。本文结合吉镍冶炼厂15 kt/a镍技术改造项目的生产实践,分析探讨了严寒地区工业给排水的设计要点。 The air temperature in winter is low in severe cold region in north China. Industrial water supply and drainage system design should adopt safe, reliable economical, technical measures to solve heat preservation and anti-freezing problems of pipeline and equipment and guarantee normal operation of industrial enterprises. The paper has analyzed and discussed the design points of industrial water supply and drainage in severe cold region based on the production practice in Ji'en Nickel Smleter 15 kt/a nickel technical upgrade project.
作者 罗路
出处 《有色冶金设计与研究》 2012年第5期29-31,共3页 Nonferrous Metals Engineering & Research
关键词 土壤冰冻线 给排水设计 覆土深度 干式系统 保温防冻措施 earth frost line water supply and drainage design covering depth dry system heat preservation and anti-freezing measures
  • 相关文献

参考文献4

  • 1GB50015-2003建筑给水排水设计规范(2009版)[S].
  • 2住房和城乡建筑部工程质量安全监管司,中国建筑标准设计研究院.全国民用建筑工程设计技术措施:给水排水[M].北京:中国计划出版社.2009.
  • 3GB50016-2006,建筑设计防火设计规范[S].
  • 4黄家晓,姜文源.自动喷水灭火系统设计手册[M].北京:中国建筑工业出版社.2002.

共引文献16