两种脉冲超声乳化模式对角膜内皮的影响 被引量:2

Comparison of the effect of two kind of phaco model on corneal endothelial cells
下载PDF
导出
摘要 目的评价白内障超声乳化摘除术中两种脉冲超声乳化模式对角膜内皮的不同影响。方法抽取2010年我院爱心复明工程行白内障手术的患者210例(210只眼),随机分为冷超声乳化组和普通超声乳化组,观察术前和术后3个月角膜内皮数目的变化。结果冷超声乳化组较普通超乳组术前和术后3个月单位面积角膜内皮数目损伤少,比较P<0.05,有统计学意义。结论冷超声乳化较普通超声乳化对角膜内皮的损伤更小。 Objective To evaluate the effect on corneal endothelial cells after cool phaco and intraocular lens im- plantation compared with regular phaecemulsification. Methods In 2010 ,totally 210 patients who will undergo phacoe- mulsitlcation in our hospital were involved in this prospective randomized study, and these patients were randomly divided into two groups, cool phaco group and regular phaco group, investigate the number of corneal endothelial cells changes on preoperative day as well as postoperative day 30. Results At preoperativdy and 30 days postoperatively, corneal endothelial cell density of cool plmco group much denser than normal phaco group, showing difference ( P 〈 0.05 ). Conclusion Cool phaco causes leas damage on corneal endothelial cells than regular phaco.
出处 《临床眼科杂志》 2012年第5期421-422,共2页 Journal of Clinical Ophthalmology
关键词 白内障 超声乳化 角膜内皮 Cataract Phacoemulsificatlon Comeal endothelial cell
  • 相关文献

参考文献5

二级参考文献28

  • 1娄晓静,孙慧敏,袁佳琴.后房人工晶体植入术后视力低于0.5的原因分析[J].实用眼科杂志,1994,12(3):154-157. 被引量:15
  • 2刘玉华,林振德.白内障摘除人工晶体植入术后低视力原因分析[J].临床眼科杂志,1996,4(3):152-153. 被引量:6
  • 3Girard LJ. Ultrasonic fragmentation for cataract extraction and cataract complications. Adv Ophthalmol, 1978, 37:127-135.
  • 4Girard LJ. Pars plana lensectomy by ultrasonic fragmentation:1984-Part Ⅱ: Operative and postoperative complications-avoidance or management. Ophthalmic Surg, 1984,15:217-220.
  • 5Agarwal A, Agarwal A, Agarwal S, et al. Phakonit: phacoemulsification through a 0.9 mm corneal incision. J Cataract Refract Surg,2001, 27:1548-1552.
  • 6Agarwal A, Agarwal S, Agarwal A, et al. Phakonit-lens removal through a 0.9 mm incision (letter). J Cataract Refract Surg, 2001,27 : 1531-1533.
  • 7Crozafon P. The use of Minimal Stress and the Teflon-Coated Tip for Bimanual High Frequency Pulsed Phaeoemulsifieation. 14th Meeting of the Japanese Society of Cataract and Refractive Surgery ,Kyoto, Japan. 1999.
  • 8Tsuneoka H, Takuya S, Takahashi Y, et al. Feasibility of ultrasound cataract surgery with a 1.4mm incision. J Cataract Refract Surg, 2001, 27:934-940.
  • 9Tsuneoka H, Shiba T, Takahashi Y, et al, Wound temperature during ultrasmall incision phacoemulsification, Nippon Ganka Gakkai Zasshi, 2001,105:237-243.
  • 10Tsuneoka H, Shiba T, Takahashi Y. Ultrasonic phacoemulsifieation using a 1.4 mm incision: clinical results. J Cataract Refract Surg,2002, 28: 81-86.

共引文献37

同被引文献16

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部