期刊文献+

陶瓷-金属封接缺陷——瓷件“光板”原因的探讨 被引量:3

Defects of Ceramic Metallization——Discussion on no Adhesive Ceramics
下载PDF
导出
摘要 采用金相、扫描电镜、能谱等分析手段,对陶瓷-金属封接的严重缺陷——瓷件"光板"的产生原因进行了分析、探讨,并提出防止光板缺陷的措施。结果表明:焊料向金属化层的严重渗透以及金属化层玻璃相的缺少,均是导致光板的主要原因。通过改进金属化工艺,保证致密的金属化层显微结构,防止焊料渗透,可以避免光板缺陷。 Defects of Ceramic Metallization were analyzed by metallographic analysis, Scanning Elec- tron Microscopy and energy dispersive X-ray spectrometer methods in this paper, and methods of avoiding no adhesive ceramic were given. The results showed that braze infiltrate into metalizing and glassy reduced are both the main reasons caused no adhesive ceramic. Though improving metalizing process, compact microstructure of metalizing and preventing metalizing penetrated by braze could avoid status of no adhesive ceramics.
出处 《真空电子技术》 2012年第4期28-33,共6页 Vacuum Electronics
关键词 金属化 活化钼锰法 光板 显微结构 Metallizing, Moly-manganese, No adhesive ceramic, Microstrueture
  • 相关文献

参考文献4

二级参考文献9

共引文献11

同被引文献10

  • 1江树儒.美国氧化铝陶瓷显微结构的研究[J].真空电子技术,1989,2(6):39-42. 被引量:5
  • 2Kingery W D, Bowen H K,Uhlman D R. Introduction to Ceramics (Second Edition)[M]. 1976.
  • 3浜野健也,吴大选,译.陶瓷的显微结构和物性[J].中国陶瓷,1984,(5).
  • 4GB/T5594.8-1985电子元器件结构陶瓷材料性能测试方法-显微结构的测定方法[s],1985.
  • 5Coble R L. Transparent Alumina and Method of Prepa- ration [P]. US: 3 026 210,1962.
  • 6Kim Byung-Ki, et al. Am Ceram Soe[J], 2003,86(4): 634.
  • 7上海科技大学.电子陶瓷显微结构图册[M].上海:华东师范大学出版社,1982.
  • 8江树儒.透明多晶氧化铝陶瓷显微结构的研究[J].特种陶瓷,1987,(2).
  • 9刘桂武,王志刚,乔冠军,王红洁,王继平.Al_2O_3的W金属化及其与Nb的Pd钎焊研究[J].稀有金属材料与工程,2009,38(8):1394-1397. 被引量:8
  • 10赵世柯.氧化铝基陶瓷Mo-Mn法金属化机理分析及实验研究[J].真空电子技术,2010,23(4):24-29. 被引量:10

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部