摘要 现代变频器电力电子产品的广泛应用,导致大量谐波电流流入电网,引起电网电压波动和闪变,造成系统电压波形严重畸变,影响系统用电设备的正常运行,严重时引起系统谐振烧毁电气设备,引发电气事故,造成巨大的经济损失,这就使得含有变频器的供配电系统无功补偿问题变得更加复杂。因此,电气设计人员必须掌握供配电系统采用变频器后功率因数的变化机理,才能合理高效地解决其无功功率补偿问题,以使设计更加安全可靠、经济实用。 The widely application of electronics products will cause great harmonic current in the power system,lead to voltage fluctuation,distortion of system voltage waveform,affection of normal operation of system equipment.Seriously,it can burn equipment,cause accident and great economy loss.This will make reactive compensation of distribution system with transducer more complex.The designer should grasp the transformation mechanism of power factors to solve reactive power compensation problems to ensure safety and economy design.
作者 牛丽英
出处 《林业科技情报》 2012年第3期63-65,共3页 Forestry Science and Technology Information
关键词 变频器 功率因数 无功补偿 transducer power factor reactive compensation
  • 相关文献

参考文献5

  • 1供配电系统设计规范GB50052-2009[S].
  • 2JGJ 16-2008 民用建筑电气设计规范[S].
  • 3中国航空工业规划设计研究院等编工业与民用配电设计手册[M].3版.北京:中国电力出版社.2005.
  • 4张燕宾.张燕宾讲变频(五) 关于变频器的功率因数[J].电气时代,2008(6):108-110. 被引量:2
  • 5哈尔滨威瀚电气设备股份有限公司产品综合样本[Z].