期刊文献+

剖析影响欧盟房间分体空调器季节能效比的技术因素

剖析影响欧盟房间分体空调器季节能效比的技术因素
下载PDF
导出
摘要 本文从欧盟ErP指令空调生态设计实施指令OJNo.206:2012中对房间空调器季节能效比(SEER)的部分负荷测试评价及季节性能计算方法入手,剖析影响欧盟房间分体空调器节能技术因素,在大力提倡节能降耗的新形式下,为房间空调器的季节能效比提供设计参考。 The article begins with the definition of the Seasonal Energy Efficiency Ratio (SEER) measuring methods of EU ERP director OJ No. 206:2012, test experiment and computing method, analyzes part load conditions and calculation of seasonal performance for EU increasing SEER of room air conditioners. With energy saving being vigorously advocated, the study can be used as a reference for the design of improving SEER of room air conditioners with low and medium energy efficiency in the situation.
作者 张文清
出处 《日用电器》 2012年第9期40-43,共4页 ELECTRICAL APPLIANCES
关键词 空调器 季节能效比SEER 节能 测试计算 air-conditioner the Seasonal Energy Efficiency Ratio energy-saving measure
  • 相关文献

参考文献3

  • 1Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling Testing and rating at part load conditions and calculation of seasonal performance for EN ]4825 Page 26-28.
  • 2Implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for air conditioners and comfort fans (OJ No. 206:2012) .
  • 3Commission Delegated Regulation (EU) No 626/2011 with regard to energy labelling of air conditioners.