摘要
本文从欧盟ErP指令空调生态设计实施指令OJNo.206:2012中对房间空调器季节能效比(SEER)的部分负荷测试评价及季节性能计算方法入手,剖析影响欧盟房间分体空调器节能技术因素,在大力提倡节能降耗的新形式下,为房间空调器的季节能效比提供设计参考。
The article begins with the definition of the Seasonal Energy Efficiency Ratio (SEER) measuring methods of EU ERP director OJ No. 206:2012, test experiment and computing method, analyzes part load conditions and calculation of seasonal performance for EU increasing SEER of room air conditioners. With energy saving being vigorously advocated, the study can be used as a reference for the design of improving SEER of room air conditioners with low and medium energy efficiency in the situation.
出处
《日用电器》
2012年第9期40-43,共4页
ELECTRICAL APPLIANCES
关键词
空调器
季节能效比SEER
节能
测试计算
air-conditioner
the Seasonal Energy Efficiency Ratio
energy-saving
measure