摘要
针对某数据中心的配电设计,介绍其配电系统的构成,分析配电系统的特点及系统运行状态,给出状态模式表。在模式表的基础上进行控制主流程分析,形成主流程分析图,细化次流程,最终形成控制方案并实施。
For the distribution design of a data center, the composition of distribution system is introduced, the features and running state of the system are analyzed, and the state model table is provided. Based on the table, the primary flow of control is analyzed with corresponding the primary flow analysis chart formed, and the secondary flow is detailed and control plan is finally made and implemented.
出处
《建筑电气》
2012年第9期34-38,共5页
Building Electricity
关键词
数据中心
配电系统
10
kV自投控制
流程分析