摘要 针对目前国内用于污水处理厂氧化沟工艺回流污泥轴流泵普遍存在电机电流超负荷现象,通过实验测试和相关理论分析得出产生该现象有两大主要原因,其一是氧化沟液流存在剧烈湍流,其二是泵吸入池有较多不对称旋涡,并提出在流道内设置导流板和吸入池增设减涡板的方法来消除该现象。 In order to eliminate the shaft flowing pump current overload which was used in delivering oxidized sludge coming from the oxidation ditch in sewage plants, it's the common difficult question which lay in mostly sewage treatment plants in China. After having done some test experiments and analyzing datas of shaft flowing pump theories, two influen- cing factors were found out that one was turbulence in oxidation ditch, and another was asmmetrical eddy in the pump suction ditch. Two settlements about eliminating it were proposed one was setting a bunch of guiding flow board in the sew- age channel, and the other was installing a certain amount of eliminating asymmetrical eddy board in the pump suction ditch.
作者 向信霖 樊星
出处 《广州化工》 CAS 2012年第18期107-109,共3页 GuangZhou Chemical Industry
基金 中国电力投资集团公司科技项目(2011-004-CQD-KJ-X) 重庆市南岸区科技攻关计划项目(市政中水高效脱碳处理技术研究与装置研制)
关键词 轴流泵 湍流 不对称旋涡 漏斗形空腔 饱和蒸气压 shaft flowing pump turbulence asymmetrical eddy infundibular cavity saturated vapour pressure
  • 相关文献

参考文献4

  • 1丁成伟.离心泵与轴流泵[M].重庆:机械工业出版社,1981:227.
  • 2[美]A.J.斯捷潘诺夫著.离心泵和轴流泵一理论、设计和应用[M].徐行健译.北京:机械工业出版社,1980:67-69.
  • 3徐刚.最新国内外水泵设计制造新工艺新技术与质量检验检测标准规范实务全书[M].北京:中国知识出版社,2006:1000-1002.
  • 4贾邦安.关于轴流泵运转中电流升高现象的分析[J].通用机械,2008(3):50-52. 被引量:1

二级参考文献1

  • 1[1]日本农业土木事业协会水泵设备研究会.泵站工程技术手册[M].丘传忻,林中卉,黄建德,等译.北京:中国农业出版社,1998.