期刊文献+

短眼轴眼不同人工晶状体计算公式准确性比较 被引量:1

The accuracies of intraocular lens ( IOL ) power calculation formulas in short-length eyes
原文传递
导出
摘要 目的比较A型超声测量下6种现代人工晶状体公式(SKT、HAIGIS、HOFFER—Q、SRK—Ⅱ、HOLLADAY、BKINK-Ⅱ)在短眼轴眼(〈22mm)的准确性应用。方法前瞻性研究短眼轴白内障眼超声生物参数,人工晶状体植入术前使用A型超声仪、角膜曲率计测量术眼的眼轴长及角膜屈光度,术后1个月电脑验光与检影验光相结合的方法测量术眼获得最佳矫正远视力时的实际屈光度数,回输超声测量的眼轴、角膜屈光度及实际使用的人工晶状体度数,并分别计算术眼用这6种公式的预期屈光度数,预期屈光度与实际屈光度之差绝对值,即绝对屈光误差值。结果HAIGIS绝对屈光误差最大(0.9181±0.10691)D(P〈0.01);其他5种公式比较无统计学意义,但SRK—Ⅱ的绝对屈光误差值最小(0.5088±0.07012)D,但在绝对屈光误差值0—0.5D范围内,SKT公式所占比例最高(34.37%)。结论在目前短眼轴样本量,除HAIGIS外,其他5种公式比较,SRK—II的绝对屈光误差值最小,SKT其次;但在绝对屈光误差0~0.5D范围内,SKT公式所占比例最高(34.37%),可见,SKT公式在短眼轴眼提供最准确的预测屈光度;HAIGIS对术后屈光度影响较大,不适合国人短眼轴眼。 Objective To explore the accuracies of intraocular lens(IOL) power calculations by u-sing 6 formulas ( SKT, HAIGIS, HOFFER-Q, SRK-Ⅱ, HOLLADAY, BKINK-Ⅱ) in Chinese short eyes. Methods Data were prospectively collected by identifying eyes of axial length below 22 mm . The axial lengths and keratometry of the 32 short eyes were measured with ultrasonic scanning before operation, and the actual postoperative refraction was measured with the methods of computer and retinoscopy optometry when patients could gain best corrected visual acuity one month after surgery or later. Inputting the axial lengths, keratometry and IOL powers into ultrasonic scanning , the predicted postoperative refraction was calculated with 6 formulas, and differences of predicted and actual postoperative refraction in short eyes were com- pared. The absolute refraction errors were the absolute value with the difference of the predicted and actual postoperative refraction. Results The differences of the absolute refraction errors were compared, there were no significant differences among 5 formulae except HAIGIS in the short eyes. Absolute refraction errors of the SRK-Ⅱ and SKT were smaller than other formulae. The distribution rate of the absolute refraction er-rors in the SKT formula was the largest from 0 to 0.50 D in Chinese short eyes. Conclutions The SKT for-mula provides the best predictive result of the absolute refraction errors from 0 to 0.50 D in Chinese short eyes . The HAIGIS is the least accurate in 6 formulae in Chinese short eyes.
出处 《中华眼外伤职业眼病杂志》 2012年第10期746-749,共4页 Chinese Journal of Ocular Trauma and Occupational Eye Disease
关键词 晶状体超声乳化 晶状体 人工 短眼轴眼 Phacoemulsification Lens, intraocular Eye, short-length
  • 相关文献

参考文献8

  • 1Norrby S. Sources of error in intraocular lens power calculation. J Cataract Refract Surg,2008,34 : 368 - 376.
  • 2Narvaez J, Zimmerman G, Stulting RD, et al. Accurary of intraoc- ular lens power prediction using the Hoffer Q, Holladayl, Holla- day2 ,and SRK-T formulars. J Cataract Refract Surg, 2006,32: 2050 - 2053.
  • 3姜燕,施玉英,杨文利.六种人工晶状体屈光度数计算公式的准确性比较[J].眼科,2007,16(2):100-103. 被引量:12
  • 4Hoffer KJ . The Hoffer Q formula : a comparison of theoretic and regression formulas. J Cataract Refract Surg, 1993,19 : 700 - 712.
  • 5Hoffer KJ. Clinical resuhs using the Holladay 2 intraocular lens power formula. J Cataract Refract Surg,2000,26:1233 - 1237.
  • 6Donoso R, Mura JJ, Lopez M, et al . Emmetropization at cataract surgery. Looking for the best IOL power calculation formula ac- cording to the eye length . Arch Soc Esp Oftalmol,2003,78:477 480.
  • 7EA Gavin, CJ Hammond. Intraocular lens power calculation in short eyes. Eye, 2008,22 : 935 - 938.
  • 8Eleftheriadis H. IOL Master biometry:refractive results of 100 con- secutive cases. Br J Ophthalmo1,2003 ,87 :960 - 963.

二级参考文献12

  • 1曹文红,施玉英,徐亮,陈长喜.可调节人工晶状体植入术后调节效果的观察[J].眼科,2006,15(1):16-20. 被引量:4
  • 2Olsen T, Thim K, Corydon L. Theoretical versus SRK I and SRK Ⅱ calculation of intraocular lens power. J Cataract Refract Surg,1990,16:217-225.
  • 3Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas. J Cataract Refract Surg, 1993,19:700-712; errata,1994,20:677.
  • 4Narvaez J, Zimmerman G, Stuhing RD, et al. Accuracy of intraocular lens power prediction using the Hoffer Q, Holladay 1, Holladay 2,and SRK/T formulas. J Cataract Refract Surg, 2006,32:2050-2053.
  • 5Holladay JT. International intraocular lens registry. J Cataract Refract Surg, 1999,25:128-136.
  • 6Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg,1992,18:125-129.
  • 7Holladay JT, Prager TC, Ruiz RS, et al. Improving the predictability of intraocular lens power calculations. Arch Ophthalmol, 1986,104:539-541.
  • 8Eleftheriadis H. IOL Master biometry: refractive results of 100 consecutive cases. Br J Ophthalmol, 2003,87:960-963.
  • 9Seizs B, Langenbucher A, Nguyen NX, et al. Underestimation of intraocular lens power for cataract surgery after myopic photorefractive keratectomy. Ophthalmology, 1999,106:693-701.
  • 10Donoso R, Mura JJ, Lopez M, et al. Emmetropication at cataract surgery. Looking for the best IOL power calculation formula according to the eye length. Arch Soc Esp Oftalmol, 2003,78:477-480.

共引文献11