期刊文献+

高低温试验能力验证常见不满意原因分析 被引量:5

Analysis on the Causes of Dissatisfactory Results in Proficiency Testing of High and Low Temperature Test
下载PDF
导出
摘要 测量审核和实验室间比对是能力验证计划的有效补充形式,是实验室或者检查机构用于实验室质量控制及申请CNAS认可的重要手段。本文随机抽取2010年~2012年低温试验测量审核与高温试验实验室间比对结果为不满意的报告各8份作为样本,进行原因分析,并给出技术建议,旨在让参加实验室在以后的相关试验中能规避常见问题,提高测试能力。 Measurement audits and interlaboratory comparison are the effective supplementary forms for proficiency testing scheme and the major means in laboratory quality control and application for CNAS accreditation for laboratories or inspection organizations.In this paper,8 reports with dissatisfactory results of low temperature test measurement audits and high temperature interlaboratory comparison from 2010 to 2012 have been chosen as samples,against which the author shall analyze on the causes and provide technical advice with an aim to help participating laboratories to avoid common problems in related tests in the future and enhance their testing capabilities.
作者 王珊珊
出处 《环境技术》 2012年第4期36-39,共4页 Environmental Technology
关键词 测量审核 实验室间比对 高低温试验 不满意原因 measurement audit interlaboratory comparison high and low temperature test causes of dissatisfaction.
  • 相关文献

参考文献4

  • 1NAS-AL07:2011《CNAS能力验证领域和频次表》.
  • 2CNAS-RL02:2010《能力验证规则》.
  • 3GB/T2423.1-2008《电工电子产品环境试验第2部分:试验方法试验A:低温》.
  • 4GB/T2423.2-2008《电工电子产品环境试验第2部分:试验方法试验B:高温》.

共引文献3

同被引文献13

引证文献5

二级引证文献6