螺旋CT低剂量扫描技术在青少年埋伏牙检查中的应用 被引量:2

下载PDF
导出
摘要 目的探讨螺旋CT低剂量扫描技术在青少年埋伏牙检查中的应用价值。方法 40例临床诊断埋伏牙拟行螺旋CT扫描的病例随机分为4组,分别运用200、150、100、35 MAS管电流进行扫描,得到4组低剂量图像,利用齿科软件进行重建。对病例作出临床诊断,并评价得到的图像质量。同时记录病例的CT剂量指数(CTDI)、有效剂量长度乘积(DLP),分析4组病例间辐射剂量的统计学差异。结果 4组病例均能做出明确的埋伏牙诊断及定位;200、150、100 MAS组间的图像质量无显著的统计学差异(Ρ均>0.05),35 MAS组与前三组间图像质量的统计学差异明显(Ρ均<0.05),但能对埋伏牙做出明确诊断及定位。4组病例各组间受辐射剂量的统计学差异显著(Ρ均<0.05)。结论在确定病例为埋伏牙而无其他病因的情况下,可以对青少年选用超低管电流35MAS进行螺旋CT检查。
出处 《中国医药指南》 2012年第26期513-514,共2页 Guide of China Medicine
关键词 埋伏牙 CT 青少年
  • 相关文献

参考文献5

二级参考文献50

  • 1Colang JE, Killion JB, Vano E. Patient dose from CT: a literature review. Radiol Technol,2007,79 : 17-26.
  • 2Brenner D J, Hall EJ. Computed tomography:an increasing source of radiation exposure. N Engl J Med,2007 ,357 :2277-2284.
  • 3Brody AS, Frush DP, Huda W, et al. Radiation risk to children from computed tomography. Pediatrics ,2007,120:677-682.
  • 4Campbell J, Kalra MK, Rizzo S, et al. Scanning beyond anatomic limits of the thorax in chest CT: findings, radiation dose, and automatic tube current modulation. AJR,2005,185 : 1525-1530.
  • 5Donnelly LF, Emery KH, Brody AS,et al. Minimizing radiation dose for pediatric body application of single-detector helical CT: strategies at a large Children's Hospital. AJR, 2001, 176: 303 -306.
  • 6Nyman U, Ahl TL, Kristiansson M, et al. Patient-circumference- adapted dose regulation in body computed tomography, a practical and flexible formula. Acta Radiol, 2005,46:396-406.
  • 7Sigal-Clinquabre AB, Hennequin R, Abada HT, et al. Low- kilovohage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Rdiology,2004,231: 169-174.
  • 8Thomas CK, Muhlenbruch G, Wildberger JE, et al. Coronary artery calcium scoring with muhislice computed tomography: in vitro assessment of a low tube voltage protocol. Invest Radiol, 2006, 41:668-673.
  • 9Heneghan JP, McGuire KA, Leder RA, et al. Helical CT for nephrolithiasis and ureterolithiasis: comparison of conventional and reduced radiation : dose techniques. Radiology, 2003,229 :575-580.
  • 10Haaga JR, Miraldi F, Maclntyre W, et al. The effect of mAs variation upon computed tomography image quality as evaluated by in vivo and in vitro studies. Radiology, 1981, 138:449-454.