摘要
目的观察医院手术部层流洁净系统运行质量,加强安全管理措施。方法通过现场仪器分析检测方法,对某医院手术部层流洁净系统运行质量进行了监测。结果各级别手术室和辅助用房在层流洁净系统运行30min后,所有部位室内环境微小气候平均合格率达到98%以上。1 000级手术区和周边区空气中沉降菌指标有97%以上达标;10万至30万级洁净区域沉降菌指标合格率均达到100%。结论该医院手术部层流洁净系统运行质量可靠,管理规范,主要靠严格执行操作规程。
Objective To observe the operation quality of laminar flow clean system in operating room so as to enhance safety management measures.Methods Through the instrumental analysis and detection methods on the field,the running quality of laminar flow clean system in operating room of this hospital was monitored.Results After the laminar flow system of each level of the operating room and ancillary rooms running for 30 min,the average pass rate of micro-climate of all parts of the indoor environment was more than 98%;that of precipitating bacterial indicators in the surgical area and the surrounding area of one thousand purification surgery air was more than 97% and that of the subsidence bacteria indicators in the 100 000-300 000 clean regional area was 100%.Conclusion The operation quality of laminar flow clean system in operating room of this hospital is reliable and the management is normative.The operating manual should be strictly executed.
出处
《中国消毒学杂志》
CAS
北大核心
2012年第9期792-793,共2页
Chinese Journal of Disinfection
关键词
层流手术室
系统安全
管理
laminar flow operating room
system security
management