摘要 用铅试金富集催化剂及含铑废水的铑并用钯作灰吹保护,得到钯、铑合粒。合粒经溶解后,用ICP-AES测定其中的铑。该法的富集效果好,钯基体对测定没有干扰,测定快速、准确,相对标准偏差小于1%(n=7),回收率大于97%。本法可用于含铑0.x%~0.000x%的测定。 Rhodium in catalysts and waste water was concentrated firstly by lead fire assay, using palla- dium as protective agent for the cupellation to produce palladium - rhodium alloy. Then the alloy was dis- solved and ICP - AES was used to measure rhodium. The results show that the enrichment by lead fire was very effective. Palladium matrix didn't interfere with the measurement. The method is time -saving and accurate. The relative standard deviation is 〈 1 (n =7) and the recovery rate is 〉97%. The method can be applied to the determination of rhodium in the range of 0. x% - 0. 000x%.
出处 《贵金属》 CAS CSCD 北大核心 2012年第3期39-41,共3页 Precious Metals
关键词 分析化学 铅试金 催化剂 铑废水 ICP analytical chemistry fire assaying catalysts rhodium water ICP Rh