期刊文献+

Surface Characterization and Cell Response of Binary Ti-Ag Alloys with CP Ti as Material Control 被引量:8

Surface Characterization and Cell Response of Binary Ti-Ag Alloys with CP Ti as Material Control
原文传递
导出
摘要 In this study, the surface passive films, dissolution behavior and biocompatibility of Ti-Ag alloys (with 5%, 10% and 20% Ag) were evaluated by X-ray diffraction (XRD) tests, electrochemical corrosion tests, X-ray photoelectron spectroscopy (XPS) tests, dissolution tests and in-vitro cytotoxicity tests. The surface films on the Ti-20Ag alloy are rich in Ti and much deficient in Ag with respect to alloy composition, as identified by XPS. Compared to CP Ti, Ti-SAg and Ti-20Ag alloys show larger impedances and lower capacitances, which can be associated with an increase of the passive layer thickness. Moreover, all Ti-Ag alloys exhibit negligible or low metal release in the test solutions. The in-vitro cytotoxicity results show Ti-Ag alloys seem to be as cytocompatible as CP Ti. From the viewpoint of surface passive film and cytotoxicity, Ti-SAg and Ti-20Ag are considered to be more suitable for dental applications. In this study, the surface passive films, dissolution behavior and biocompatibility of Ti-Ag alloys (with 5%, 10% and 20% Ag) were evaluated by X-ray diffraction (XRD) tests, electrochemical corrosion tests, X-ray photoelectron spectroscopy (XPS) tests, dissolution tests and in-vitro cytotoxicity tests. The surface films on the Ti-20Ag alloy are rich in Ti and much deficient in Ag with respect to alloy composition, as identified by XPS. Compared to CP Ti, Ti-SAg and Ti-20Ag alloys show larger impedances and lower capacitances, which can be associated with an increase of the passive layer thickness. Moreover, all Ti-Ag alloys exhibit negligible or low metal release in the test solutions. The in-vitro cytotoxicity results show Ti-Ag alloys seem to be as cytocompatible as CP Ti. From the viewpoint of surface passive film and cytotoxicity, Ti-SAg and Ti-20Ag are considered to be more suitable for dental applications.
出处 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2012年第9期779-784,共6页 材料科学技术(英文版)
基金 supported by the National Basic Research Program of China ("973 Program", Nos.2012CB619102 and 2012CB619100) the National High Technology Research and Development Program of China ("863 Program", Nos. 2011AA030101 and2011AA030103) the National Natural Science Foundation of China (Nos. 31170909 and 51041004) the Research Fund for the Doctoral Program of Higher Education (No. 20100001110011) the Fundamental Research Funds for the Central Universities (Nos. HEUCFZ1017and HEUCFR1020) the Natural Science Foundation of Heilongjiang Province, China (No. ZD201012)
关键词 Ti-Ag alloy SURFACES Electrochemical corrosion CYTOTOXICITY Ti-Ag alloy Surfaces Electrochemical corrosion Cytotoxicity
  • 相关文献

参考文献18

  • 1D.M. Brunette, P. Ten gvall , M. Textor and P. Thomsen: Titanium in Medicine, Springer, Berlin, 2001.
  • 2M. Niinomi: Mater. Sci. Eng. A, 1998, 243, 231.
  • 3M. Takahashi, M. Kikuchi and Y. Takada: Dent. Mater. J., 2002, 21, 270.
  • 4KT. Oh, H.M. Shim and KN. Kim: J. Biomed. Mater. Res. Part B, 2005, 74, 649.
  • 5S.B. Hong, N. Eliaz, E.M. Sachs, S.M. Allen and RM. Latanision: Corros. Sci., 2001, 43, 1781.
  • 6B.B. Zhang, Y.F. Zheng and Y. Liu: Dent. Maier., 2008, 25, 672.
  • 7B.B. Zhang, B.L. Wang, L. Li and Y.F. Zheng: Dent. Maier., 2011, 27, 214.
  • 8A. Ewald, S.K Gliickermann, R Thull and U. Gbureck: Biomed. Eng. Online, 2006, 5, 22.
  • 9X.N. Gu, Y. F. Zheng, Y. Cheng and S.P. Zhong: Biomaterials, 2009, 30, 484.
  • 10A.P.R Alves, F.A. Santana, L.A.A. Rosa, S.A. Cursino and E.N. Codaro: Mater. Sci. Eng. C,2004, 24,693.