摘要 目的分析运动、容器材质、抗凝剂种类、存放条件等检测前因素对N末端B型尿钠肽原(N terminal-pro-b-type natriuretic peptide,NT-proBNP)检测结果的影响。方法采用电化学发光法,分别检测不同材质容器、不同种类抗凝剂和不同存放条件下74例心衰患者和70名健康人血液中NT-proBNP水平,以及70名健康人运动前、后的NT-proBNP水平。结果行走20 min后健康组NT-proBNP浓度较安静状态升高10%~20%,差异有统计学意义。玻璃促凝管和塑料促凝管两种不同材料的容器对NT-proBNP检测值无影响。EDTA抗凝血浆的NT-proBNP检测值较肝素锂抗凝血浆与促凝血清低,差异有统计学意义。肝素锂抗凝血浆与促凝血清的结果差异无统计学意义。常温加盖存放3 d或反复冻融3次均不影响NT-proBNP检测结果。结论 NT-proBNP检测对存放条件要求不高,但运动和抗凝剂的选用会影响NT-proBNP的水平,临床检测时应加以标化,避免检测结果的波动。 Objective To understand the influence of pre-test factors on the N terminal-pro-b-type natriuretic peptide(NT-proBNP) detection value.Methods Serum NT-proBNP levels were measured by electrochemiluminescence for 74 patients with heart failure and for 70 healthy controls using serum samples collected before and after exercise,stored in different containers,with different decoagulant and stored under different conditions.The difference on the detection value was analyzed with SPSS 13.0 software.Results The serum NT-proBNP concentration in healthy controls increased by 10%-20% after walking for 20 minutes(P0.05).The NT-proBNP concentration in glass coagulated tubes was similar to that in plastics coagulated tubes and in heparin lithium anticoagulated tuber,and the NT-proBNP concentrations in these containers were significantly higher than those in the EDTA anticoagulated tubes(P0.05).The serum stored at room temperature for 3 days or frozen thawing for 3 times had no influence on the detection value.Conclusion The serum NT-proBNP concentration would be influenced by the exercise before test and EDTA anticoagulated tubes,it is necessary to conduct standardized operation in test to obtain accurate detection result.
出处 《疾病监测》 CAS 2012年第9期738-739,756,共3页 Disease Surveillance
关键词 N末端B型尿钠肽原 慢性心力衰竭 检测前 影响因素 N terminal-pro-b-type natriuretic peptide chronic cardiac failure pre-test influential factor
  • 相关文献

参考文献8

  • 1Tang WH, Francis GS, Morrow DA, et al. National academy of clinical biochemistry laboratory medicine practice guidelines: clinical utilization of cardiac biomarker testing in heart failure [J]. Circulation ,2007,116 : e99 - 109.
  • 2Apple FS, Wu AH, Jaffe AS, et al. National academy of clinical biochemistry and IFCC committee for standardization of markers of cardiac damage laboratory medicine practice guidelines:analytical issues for biomarkers of heart failure[ J]. Circulation, 2007,116 : e95 - 98.
  • 3Remme WJ, Swedberg K. Guidelines for the diagnosis and treatment of chronic heart failure. Task force for the diagnosis and treatment of chronic heart failure. European Society of Cardiology[ J]. Euro Heart J,2001,22 :1527 - 1560.
  • 4Hunt SA, Abraham WT, Chin MH, et al. ACC/AHA 2005 guideline update for the diagnosis and management of chronic heart failure in the adult [ J ]. Circulation, 2005,112 : e154 - 235.
  • 5Lippi G, Guidi GC,Mattiuzzi C, et al. Preanalytical variability: the dark side of the moon in laboratory testing [ J ]. Clin Chem Lab Med,2006,44( 4 ) :358 -365.
  • 6Ala-Kopsala M, Magga J, Peuhkurinen K, et al. Molecular heterogeneity has a major impact on the measurement of circulating N-terminal fragments of A and B-type natriuretic peptides[ J]. Clin Chem,2004,50(9) : 1576 - 1588.
  • 7Wu AH, Packer M, Smith A, et al. Analytical and clinical evaluation of the bayer ADVIA centaur automated B-Type natriuretic peptide assay in patients with heart failure:a muhisite study[J]. Clinical Chemistry ,2004,50(5 ) :867 - 873.
  • 8Sokoll LJ, Baum H, Collinson PO, et al. Multicenter analytical performance evaluation of the Elecsys proBNP assay[J].Clin Chem Lab Med,2004,42( 8 ) :965 -972.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部