摘要 围绕某省人防地下指挥中心渗漏的治理,分析了渗漏原因,介绍了治理方案和具体施工工艺。根据该地下室的渗漏情况,外墙采用新型刚性防水材料ER防水防腐胶泥进行背水面抹面处理;后浇带采用聚氨酯灌浆材料化学注浆和ER防水防腐胶泥抹面处理相结合的方法,取得了预期的治理效果。 This article analyses leakage causes of an underground civil air defense command center, introducing the treatment and construction technology. According to the basement leakage situation, a new rigid waterproofing material called ER waterproof and anticorrosive daub was applied in the negative side of exterior wail. The combination of polyurethane grouting material and ER waterproof and anticorrosive daub was used in post-cast strip. The above measures achieved expected effects.
出处 《中国建筑防水》 2012年第20期24-26,共3页 China Building Waterproofing
关键词 人防工程 渗漏治理 背水面 刚性防水材料 ER防水防腐胶泥 civil air defense engineering leakage treatment negative side rigid waterproofing materials ER waterproof andantieorrosive daub
  • 相关文献

参考文献2

二级参考文献4

  • 1李承刚.论建筑防水的多元化[J].中国建筑防水,2005(12):4-6. 被引量:3
  • 2王铁梦.化学灌浆是工程结构裂缝控制的重要组分是工程质量的最后保证[C]//中国重庆首届化学灌浆与防水堵漏裂缝技术控制技术研讨会论文集,2006.
  • 3JC474--2008砂浆、混凝土防水剂[S].北京:中国建材工业出版社.2008.
  • 4GB50367--2006混凝土结构加固设计规范(附录A)[S].北京:中国建筑工业出版社,2006.