摘要
介绍了浙江省火电厂应对旁路铅封采取的措施,比对了铅封前后旁路开启的情况和造成的影响,对造成旁路开启的原因进行了分析,提出了实施取消旁路应关注的要点。
The measures adopted by the power plants for FGD bypass sealing were introduced. The opening con- ditions comparisons between bypass sealing before and after are discussed. Through the reasons analysis of FGD bypass opening,important measures such as present system evaluation,fuel guarantee,operation optimi- zing,and communication with EPA are put forward for the bypass canceling.
出处
《电力科技与环保》
2012年第5期21-24,共4页
Electric Power Technology and Environmental Protection
关键词
FGD旁路
现状
取消
对策
FG D bypass
opening status
canceling
measures