摘要
对猪瘟抗体间接ELISA检测试剂盒的稳定性及保存条件等进行了摸索,确定该试剂盒具有良好的稳定性,并可在2℃~8℃环境中的保存9个月。同时,测定了本试剂盒与荧光抗体病毒中和试验的符合率为92.62%;并将该试剂盒应用于免疫动物抗体的动态监测。
In this study, the repeatability and reproducibility and shelf-life of the Indirect ELISA kit to detect antibody against Classical Swine Fever Virus (I-ELISA) were explored. The results showed that theELISA kit had differences either in the same batch or in different batches and it could be kept at 2~8℃for 9 months. In addition, hundreds of pig sera were detected by the I- ELISA kit and fluorescent antibody "virus neutralization test (FVNT). The results showed that their coincidence rate was 92.62%. And the kits were also used to monitor the antibodies of vaccinated pigs dynamically.
出处
《中国兽医杂志》
CAS
北大核心
2012年第9期21-24,I0001,共5页
Chinese Journal of Veterinary Medicine
基金
农业部"948"项目(2006-G57)
国家科技支撑计划(2006BAD06A12
2006BAD06A18)