期刊文献+

应用iDose^4软件对低剂量胸部CT增强扫描图像质量的影响 被引量:4

Evaluation on impact of iDose^4 on dose reduction and image quality of low dose contrast-enhance chest CT
下载PDF
导出
摘要 目的评价将iDose4迭代重建(IR)技术用于胸部低剂量增强扫描的可行性。方法选取71例体质量指数(BMI)正常(18.5≤BMI<25.0kg/m2)且接受胸部CT增强扫描的患者,随机分为A组(120kVp,100 mAs)、B组(80kVp,100mAs)、C组(120kVp,50mAs),分别采用iDose4 IR技术和FBP进行重建,记录各组的噪声、SNR、CNR和有效剂量(ED)。按1~3分评价各组总体图像质量,并对3组结果进行比较。结果比较同一个患者的FBP和IR图像,IR技术明显降低了图像的噪声,提高了图像的SNR、CNR。B、C组IR后的图像噪声、SNR和CNR与A组FBP图像比较差异均无统计学意义(P均>0.05)。B、C组IR后的图像总体质量与A组FBP重建图像质量差异无统计学意义(P>0.05)。结论运用IR技术进行低剂量胸部CT增强扫描可获得满足诊断要求的图像。 Objective To evaluate the feasibility of using iterative reconstruction (IR) algorithm (iDose4) in low dose contrast-enhanced chest CT. Methods Seventy-one patients with normal body mass index (BMI, 18.5--25.0 kg/m2) un- derwent contrast-enhanced chest CT. The patients were randomly assigned into 3 groups: group A, 120 kVp/100 mAss group B, 80 kVp/100 mAss group C, 120 kVp/50 mAs. All images were reconstructed using conventional filtered back projection (FBP) and IR. The mean image noise, SNR, CNR and effective dose (ED) with each protocol were assessed. Image quality were graded (scale.. 1--3) and compared among 3 groups. Results For the same patient, IR significantly de- creased the mean image noise, improved SNR and CNR compared with FBP. The mean image noise, SNR and CNR using IR in group B and C were improved or comparable to those in group A using FBP (all P〉0.05). No significant difference was found in subjective image quality between groups B and C using IR, nor with group A using FBP (P〉0.05). Conclu- sion It is feasible to obtain images qualified for diagnosis using IR in low dose contrast-enhanced chest CT examination.
出处 《中国介入影像与治疗学》 CSCD 2012年第10期762-765,共4页 Chinese Journal of Interventional Imaging and Therapy
基金 国家自然科学基金(81071155 81171333) 上海市科委科研计划重点项目(10411952800)
关键词 辐射剂量 体层摄影术 X线计算机 胸部 迭代重建 图像质量 Radiation dosage Tomography, X-ray computed Chest Iterative reconstruction Image quality
  • 相关文献

参考文献5

  • 1Marin D, Nelson RC, Schindera ST, et al. Low-tube voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iter ative reconstruction algorithm--initial clinical experience. Radiol- ogy, 2010,254(1) :145-153.
  • 2Valentin J. International commission on radiation protection. Managing patient dose in multidetector computed tomography (MDCT) : ICRP Publication 102. Ann ICRP, 2007, 37(1) : 1- 79.
  • 3Berrington, De Gonzdlez A, Darby S. Risk of cancer from diag- nostic X-rays: Estimates for the UK and 14 other countries. Lancet, 2004,363(9406) :345 351.
  • 4Hu XH, Ding XF, Wu RZ, et al. Radiation dose of non-en hanced chest CT can be reduced 400- by using iterative Recon- struction in image space. Clin Radiol, 2011,66(11):1023 1029.
  • 5Hosch W, Stiller W, Mueller D, et al. Reduction of radiation exposure and improvement of image quality with BMI-adapted prospective cardiac computed tomography and iterative Recon- struction. 2011.

同被引文献36

  • 1刘勇,张华.ALARA理论及CT低剂量应用研究进展[J].中国医学影像技术,2008,24(S1):17-20. 被引量:28
  • 2谢新红,林土兴.MSCT颅底低剂量扫描的层厚选择[J].中国医学影像技术,2009,25(S1):184-186. 被引量:1
  • 3刘昌盛,魏文洲,郑晓华,童世平,殷响林,杨洪飙.低剂量CT扫描对婴幼儿颅脑病变检查的防护价值[J].中华放射医学与防护杂志,2004,24(3):270-271. 被引量:67
  • 4占杰,余晓锷.CT空间分辨率自动检测的研究与实践[J].CT理论与应用研究(中英文),2006,15(2):43-46. 被引量:8
  • 5Slovis TL. The ALARA concept in pediatric CT: Myth or reality? Radiology, 2002,223(1):5-6.
  • 6Tack D, De Maertelaer V, Gevenois PA. Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR Am J Roentgenol, 2003,181(2):331-334.
  • 7Mi6ville FA, Gudinehet F, Brunelle F, et al. herative Recon- struction methods in two different MDCT scanners: Physical metrics and 4-alternative forced-choice detectability experi- ments--a phantom approach. Phys Med, 2013,29(1) :99-110.
  • 8Funama Y, Taguchi K, Utsunomiya D, et al. ('ombination of a low tube voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographie angiogra- phy. J Comput Assist Tomogr, 2011,35(4):480-485.
  • 9Bongartz G, Golding SJ, Jurik AG, et al. European Guidelines on Quality Criteria for Computered Tomography. Luxembourg: Office for Official Publications of the European Communities, 1999:1-114.
  • 10Droege RT, Morin RL. A practical method to measure the MTF ofCTscanners. Med Phys, 1983,9(5):758-760.

引证文献4

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部