摘要 目的设计制作生物安全性的下颈椎个性化导航模板,并评价其精度。方法选取4具下颈椎防腐标本,CT扫描后,利用三维重建及快速成型技术设计制作生物安全性的后路经椎弓根个性化导航模板,在标本上辅助克氏针置入。再次CT扫描并三维重建,计算实际克氏针与虚拟克氏针的位置参数,通过配对样本T检验检测两者之间的差异;并计算虚拟克氏针与实际克氏针的位置偏差。结果虚拟和实际克氏针在X、Y、Z轴的位移和旋转均无统计学差异(P>0.05);实际克氏针与虚拟克氏针之间的偏差,X、Y、Z轴的位移偏差分别为(1.58±0.66)、(1.96±0.84)、(2.33±1.15)mm;X、Y、Z轴的旋转偏差分别为(1.43±1.18)°、(2.43±1.67)°、(1.14±0.50)°。结论本研究提出了一种可行的新型生物安全的导航模板的制作方法,其造型及精度尚需进一步改进。 Objective To develop a biological-safe patient-specific navigation template of posterior transpedicular fixation of lower cervical vertebrae and evaluate its accuracy in assisting screw inserting. Methods 4 formalin-fixed lower cervical spine specimens (C3-C7) were harvested and CT scanned. With the technologies of 3D reconstruction, rapid prototyping and molding, biological-safe patient-specific navigation templates of posterior transpedicular fixation of lower cervical vertebrae were developed. With the assist of the navigation template, Kirschner wires were inserted into the pedicles of cervical vertebrae. After second CT scan and 3D reconstruction, the positions of virtual and actual Kirschner wires were calculated and statistically analyzed by paired-sample T test to evaluate its feasibility. The position deviations were also calculated to evaluate its accuracy. Results There were no significant difference between the position of virtual and actual Kirschner wires in all displacement and rotation directions (P〉0.05). The X, Y and Z axis displacement deviations were (1.58±0.66) mm, (1.96±0.84) mm and (2.33±1.15) mm, respectively. The X, Y and Z axis rotation deviations were (1.43±1.18)°, (2.43±1.67)° and (1.14±0.50)°, respectively. Conclusions The developed navigation template is feasible for posterior transpedicular fixation of lower cervical vertebrae, however, it's model shape and accuracy need further improvement.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2012年第5期509-512,共4页 Chinese Journal of Clinical Anatomy
基金 国家自然科学基金(61190120 6110922 6110923) 广东省教育部产学研结合项目(2010B090400425) 广东省自然科学基金(S2011010004179)
关键词 下颈椎 导航模板 椎弓根固定 生物安全性 快速成型 Lower cervical spine Navigation template Pedicular fixation Biological safe Rapid prototyping
  • 相关文献

参考文献10

  • 1Abumi K, Itoh H, Taneichi H, et al. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report [J]. J Spinal Disord,1994,7(1): 19-28.
  • 2Panjabi M M, Shin E K, Chen N C, et al. Internal morphology of human cervical pedicles.[J]. Spine, 2000, 25(10): 1197-1205.
  • 3Rampersaud YR, Simon DA, Foley KT. Accuracy requirements for image-guided spinal pedicle screw placement. [J]. Spine, 2001,26 (4): 352-359.
  • 4尹庆水,万磊,夏虹,艾福志,马向阳,王建华.计算机辅助设计寰枢椎椎弓根内固定数字化导向模板精确置钉[J].中华骨科杂志,2009,29(12):1089-1092. 被引量:19
  • 5Lu S, Xu YQ, Zhang YZ, et al. A novel computer-assisted drill guide template for placement of C2 laminar screws[J]. Eur Spine J,2009,18(9): 1379-1385.
  • 6Kunz M, Rudan J F, Xenoyarmis G L, et al. Computer-Assisted Hip Resurfacing Using Individualized Drill Templates [J]. J Arthroplasty, 2009: 600-606.
  • 7Goffin J, Van Brussel K, Martens K, et al. Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C 1 -C2 [J]. Spine, 2001,26( 12): 1343-1347.
  • 8Lu S, Xu YQ, Lu WW, et al. A novel patient-specific navigational template for cervical pedicle screw placement [J]. Spine, 2009, 34(26): E959-E966.
  • 9毛广平,周长圣,赵建宁,陈跃先,李洋,邱阳,卢光明.快速成型颈椎模型的精度测定及其用于术中置钉导向的可行性研究[J].中国脊柱脊髓杂志,2010,20(12):1008-1013. 被引量:6
  • 10D'Urso PS, Williamson OD, Thompson RG. Biomodeling as an aid to spinal instrumentation.[J]. Spine, 2005, 30(24):2841-2845.

二级参考文献10

  • 1Sykes LM,Parrott AM,Owen CP,et al.Applications of rapid prototyping technology in maxillofacial prosthetics[J].Int J Prosthodont,2004,17 (4),454-459.
  • 2Galantucci LM,Percoco G,Angelelli G,et al.Reverse engineering techniques applied to a human skull,for CAD 3D reconstruction and physical replication by rapid prototyping[J].J Med Eng Technol,2006,30(2):102-111.
  • 3Yamazaki M,Okawa A,Akazawa T,et al.Usefulness of 3 dimensional full scale modeling for preoperative simulation of surgery in a patient with old unilateral cervical fracture dislocation[J].Spine,2007,32 (18):E532-536.
  • 4Izatt MT,Thorpe PL,Thompson RG,et al.The use of physical biomodelling in complex spinal surgery[J].Eur Spine J,2007,16(9):1507-1518.
  • 5Guarino J,Tennyson S,McCain G,et al.Rapid prototyping technology for surgeries of the pediatric spine and pelvis:benefits analysis[J].J Pediatr Orthop,2007,27(8):955-960.
  • 6Mizutani J,Matsubara T,Fukuoka M,et al.Application of full scale three dimensional models in patients with rheumatoid cervical spine[J].Eur Spine J,2008,17(5):644-649.
  • 7Lu S,Xu YQ,Lu WW,et al.A novel patient-specific navigational template for cervical pedicle screw placement[J].Spine,2009,34 (26):E959-964.
  • 8D'Urso PS,Williamson OD,Thompson RG.Biomodeling as an aid to spinal instrumentation[J].Spine,2005,30 (24):2841-2845.
  • 9Owen BD,Christensen GE,Reinhardt JM,et al.Rapid prototype patient specific drill template for cervical pedicle screw placement[J].Comput Aided Surg,2007,12 (5):303-308.
  • 10Rodenwaldt J,Kopka L,Roedel R,et al.3-D virtual endoscopy of the upper airway:optimization of the scan parameters in a cadaver phantom and clinical assessment[J].J Comput Assist Tomogr,1997,21 (3):405-411.

共引文献23

同被引文献123

引证文献5

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部