应用能谱CT MARS技术评价胫骨平台骨折内固定术后疗效 被引量:8

Evaluation of the intra-articular fixation for tibial plateau fracture by spectral CT with metal artifacts reduction system
下载PDF
导出
摘要 目的评价能谱CT金属伪影去除系统(MARS)技术对胫骨平台骨折钢板内固定术的疗效评价。方法对23例胫骨平台骨折钢板内固定术后患者行宝石能谱CT检查,对原始图像用设备自带软件包进行金属伪影去除处理和膝关节三维重建。以原始图像为参照,比较去伪影图像对胫骨平台骨折钢板内固定术的显示效果。结果宝石能谱CT图像较常规图像金属伪影明显减少,能够更清晰地显示骨折复位和内固定术的修复效果。结论宝石能谱CT伪影去除效果明显,是胫骨平台骨折内固定术疗效评价的有用手段。 Objective To assess the effect of intra-articular fixation for tibial plateau fractures by spectral CT with metal artifacts reduction system(MARS).Methods After the intra-articular fixation,23 patients with tibial plateau fracture were examined by GE gemstone spectral imaging(GSI) CT.The reconstruction images were obtained by reducing the original images’ metal artifacts.Three-dimensional reconstruction was simultaneously performed.Then the reconstruction images were compared with the original images.Results Compared with ordinary CT,the metal artifacts in reconstructed images were significantly reduced.The GSI CT can better assess the effect of intra-articular fixation for tibial plateau fractures.Conclusion Spectral CT with MARS can be used to evaluate the effect of intra-articular fixation for tibial plateau fractures.
出处 《上海医学影像》 2012年第3期179-181,共3页 Shanghai Medical Imaging
关键词 胫骨平台骨折 关节内固定术 能谱CT 金属伪影去除术 Tibial plateau fracture Intra-articular fixation Spectral computed tomography Metal artifacts reduction system
  • 相关文献

参考文献5

  • 1BARRETT J F, KEAT N. Artifacts in CT: recognition and avoidance [J]. Radiographics, 2004, 24(6): 1679-1691.
  • 2BROOK O R, GOURTSOYIANNI S, BROOK A, et al. Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers [J]. Radiology, 2012, 263(3): 696-705.
  • 3周泽俊,胡永胜,高斌,巢惠民.多层螺旋CT图像伪影的分析[J].中国CT和MRI杂志,2008,6(5):72-73. 被引量:53
  • 4ZHANG Y, ZHANG L, ZHU X R, et al. Reducing metal artifacts in cone-beam CT images by preprocessing projection data [J]. Int J Radiat Oncol Biol Phys, 2007, 67(3): 924-932.
  • 5谷建伟,张丽,陈志强,邢宇翔.CT图像中金属伪影的快速校正[J].中国体视学与图像分析,2005,10(2):108-111. 被引量:21

二级参考文献14

  • 1王学礼.医用CT图像常见伪影成因及矫正分析[J].CT理论与应用研究(中英文),2004,13(3):1-8. 被引量:22
  • 2谷建伟,张丽.圆轨迹锥束CT的伪影成因和校正方法综述[C].北京:CT和三维成像学术年会论文集,2004.12-16.
  • 3Lewitt RM, Bates R H. Image reconstruction from projections( Ⅲ ): Projection completion methods [ J]. Optik,1978, 50:189-204.
  • 4Kalender W A, Hebel R, Ebersberger J. Reduction of CT artifacts caused by metallic implants[J]. Radiology,1987, 164(2): 576 -577.
  • 5ZHAO Shiying, Douglas D. Robertson, et al. X-ray CT metal artifacts reduction using wavelets: an application for imaging total hip prostheses[ J]. IEEE Trans on Medical Imaging, 2000, 19(12) :1238 - 1247.
  • 6Medoff B Petal. Iterative convolution backprojection algorithms for image reconstruction from limited data [ J ].Journal of Optical Society of America, 1983, 73 ( 11 ):1493 - 1500.
  • 7WANG G, Donald L Snyder, Joseph A OSullivan, et al.Iterative deblurring for CT metal artifact reduction [ J ].IEEE Trans on Medical Imaging, 1996,15 (5):657 -664.
  • 8XIA Dan, Roeske John C, YU Lifeng, et al. A hybrid approach to reducing computed tomography metal artifacts in intracavitary brachytherapy [ J ]. Brachytherapy,2005, 4(1): 18 -23.
  • 9CHEN Laigao, Liang Yun, George A Sandison, et al, A novel method for reducing high attenuation object artifacts in CT reconstructions [ J]. Proceedings of SPIE, 2002,4684: 841 - 850.
  • 10P Joseph, R Spital, A method for correction bone induced artifacts in computed tomography scanners [ J ]. J Comput. Assist. Tomogr. , 1978, 2: 100 - 108.

共引文献67

同被引文献72

  • 1谷建伟,张丽,陈志强,邢宇翔.CT图像中金属伪影的快速校正[J].中国体视学与图像分析,2005,10(2):108-111. 被引量:21
  • 2LEE Y H, PARK K K, SONG H T, et al. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software[J]. Eur Radiol, 2012, 22(6), 1331-1340.
  • 3WANG Y, QIAN B, LI B, et al. Metal artifacts reduction using monochromatic images from spectral CT: evaluation of pedicle screws in patients with scoliosis [J]. Eur J Radiol, 2013, 82(8): e360-e366.
  • 4StRADIOTTI P, CURTI A, CASTELLAZZI G, et al. Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art[J]. Eur Spine J, 2009, 18(Suppl1): 102-108.
  • 5BOAS F E, FLEISCHMANN D. Evaluation of two iterative techniques for reducing metal artifacts in computed tomography [J]. Radiology, 2011, 259 (3) : 894-902.
  • 6BROOK O R, GOURTSOYIANNI S, BROOK A, et al. Spectral CT with metal artifacts reduction software for improvement of tumor visibility in the vicinity of gold fiducial markers[J]. Radiology, 2012, 263 (3) : 696-705.
  • 7LIU P T, PAVLICEK W P, PETER M B, et al. Metal artifact reduction image reconstruction algorithm for CT of implanted metal orthopedic devices: a work in progress [J]. Skeletal Radiol, 2009, 38(8): 797-802.
  • 8Feng H,Tan H,Kiya K,et al.Three-di mensional CT angiography and surgical correlation in the evaluation of intracranial aneurysm[J].Chin Med J(Engl),2002,115:146.
  • 9Pechlivanis I,Schmieder K,Scholz M,et al.3-D imensional computed tomographic angiography foruse of surgery planning in patients with intracranial aneurysms[J].Acta Neurochir(Wien),2005,147:1045.
  • 10Tomandl BF,Hammen T,Klotz E,et al.Bone-subtraction CT angiography for the evaluation of intracranial aneurysms[J].AJNR Am J Neuroradiol,2006,27(1):55-59.

引证文献8

二级引证文献112

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部