摘要 为了确保蒸汽发生器运行的安全与可靠,需要计算确定其运行极限。确定运行极限需考虑的主要因素有一次侧与二次侧压力差、出口湿蒸汽含量、管系振动。如果将蒸汽发生器运行时的一次侧平均温度或二次侧饱和压力标识在运行极限图上,就可以直观判断蒸汽发生器的运行是否安全,预判运行可能产生的问题。 The operating limits should be determined to make sure the steam generator is safe and reliable.The pressure difference between the primary and secondary sides,the moisture content of steam,the tube bundle vibration are the main factors to be considered.If the average temperature at primary side or the saturation pressure at secondary side is indicated on the operating limits curve,the operation safety or the reason for possible operation problems can be identified more directly.
出处 《中国核电》 2012年第3期225-227,共3页 China Nuclear Power
关键词 运行极限 压力差 湿蒸汽含量 管系振动 蒸汽发生器 operating limits pressure difference moisture content tube bundle vibration steam generator
  • 相关文献

参考文献2

  • 1John G. Collier, John R. Thome. Convective Boiling and Condensation [J].
  • 2M. K. Au-Yang. Flow induced vibration of power and process plant components [J].

同被引文献6

  • 1张东辉.钠冷快堆安全分析[R].北京:中国原子能科学研究院,2002.
  • 2蒸汽发生器设计说明书[R].北京:中国原子能科学研究院,1997.
  • 3凯达洛夫BB,巴尔捷涅夫BH,法拉克申MP,等.蒸汽发生器SG-33运行手册[M].下诺夫格罗德:俄罗斯液压机设计试验局,2000.
  • 4中国实验快堆稳态运行工况分析报告[R].北京:华北电力大学核科学与工程学院,2010.
  • 5WILLBYETAL C. Material choices for the com- mercial fast reactor steam generator[R]. Lon- don: BNES, 1978.
  • 6International Working Group on Fast Reactors. Specialists' Meeting on Theoretical and Experi- mental Work on LMFBR Steam Generator Integ- rity and Reliability with a Particular to Leak De- velopment and Detection[C]. Netherlands: [s. n. ], 1983.