期刊文献+

不同厚度铅胶板对介入手术操作位置散射线的屏蔽效果研究 被引量:4

Study on screen effect of lead ruber plate varying thickness to scatted rays in intervening operation area
下载PDF
导出
摘要 目的 :为选择放射介入手术者个人防护用品的最佳防护厚度提供科学依据。方法 :模拟放射介入手术条件 ,测量不同厚度的铅胶板对介入手术者身体主要部位散射线的防护效果。结果 :4种不同防护厚度 (0 1,0 2 ,0 2 5 ,0 35mm铅当量 )的铅胶板对介入手术者头、胸、腹、下肢散射线的屏蔽效率分别为 84 4%~ 93 0 % ,92 9%~ 97 0 % ,94 2 %~ 98 2 %和 95 8%~ 98 5 %。结论 :介入手术者的防护服前身以 0 2 5~ 0 3 ,后身以 0 1~ 0 15mm铅当量为宜 ,防护帽帽沿和帽顶的最佳防护厚度分别为 0 2 5和 0 1mm铅当量 ;防护眼镜或防护面罩最适宜的防护厚度为 0 2 5~ 0 Objective The objective of this study is to provide scientific data for the most suitable protective depth of the individual protective article for the radio-interventional operaters.Methods The simulated conditions of radio-interventional operations were made,and the protective results of the lead rubber(of various depthes)to the scattered radiation upon the main parts of the operaters were then measured.Results The results were satisfactory:the shield effect rate of the lead rubber(0.1,0.2,0.25,0.35mm lead equivalent respectively)to the head,chest,abdomen and the lower extremities was 84.4%~930%,929%~970%,942%~982% and 958%~985% respectively.Conclusion It is suggested that the optimizational values of the projective depthes of different parts of the protective article were 0.25~0.30mm lead equivalent for the front part of the protective clothe,0.1~0.15mm lead equivalent for the back of the clothe;0.25 and 0.1mm lead equivalent for the brim and top of the protective hat respectively;and 0.25~0.30mm lead equivalent for the protective glasses and the protective mask.
出处 《中国辐射卫生》 2000年第2期72-73,共2页 Chinese Journal of Radiological Health
关键词 介入放射学 放射防护 个人防护用品 Interventional radiology Radiation protection Individual protective articles
  • 相关文献

参考文献1

二级参考文献8

  • 1-.UNSCEAR 1993年报告.电离辐射源与效应[M].北京:原子能出版社,1995.229-230.
  • 2袁志强,中华放射医学与防护杂志,1998年,18卷,117页
  • 3侯金鹏,中国辐射卫生,1997年,6卷,216页
  • 4Li L B,Health Phys,1995年,69卷,261页
  • 5UNSCEAR 1993报告.电离辐射源与效应,1995年,229页
  • 6GB8279 87 医用诊断X线卫生防护标准
  • 7侯金鹏,邓大平,朱建国,冯涛,陈玉祥,李占来,陆鸿.聊城地区放射工作人员个人剂量监测与分析[J].中国辐射卫生,1997,6(4):216-217. 被引量:34
  • 8袁志强,林秀华,刘晓虹.介入治疗的X射线防护监测与评价研究[J].中华放射医学与防护杂志,1998,18(2):117-120. 被引量:25