期刊文献+

能量多普勒显像在软组织实性肿块血供检测中的初步应用 被引量:4

Preliminary Application of Doppler Power Imaging Detection of Solid Tumors in Soft Tissue
下载PDF
导出
摘要 目的 探讨能量多普勒显像 (PDI)对软组织实性肿块的诊断价值。方法 应用CDFI、PDI技术检查 45例软组织实性肿块病人 ,分析CDFI、PDI血流检出率及血流信号分级。结果  45例软组织实性肿块中良性肿块 2 4例 ,恶性肿瘤为 2 1例 ,PDI血流检出率高于CDFI ,P <0 0 1 ;以血流信号Ⅱ~Ⅲ级判断为恶性肿瘤 ,0~Ⅰ级判断为良性肿块 ,PDI、CDFI对良恶性肿瘤鉴别均有统计学意义。且PDI假阴性为 0 ,CDFI假阴性为 1 9 0 %。结论 PDI血流敏感性高于CDFI。 Objective To discuss the value of diagnosing the soft tissue masses by Doppler Power Imaging. Methods CDFI and DPI were performed in 45 cases of tissue masses in order to analize the blood flow detection rates of CDFI and PDI and the degree of blood flow signals. Results Of these 45 cases,24 cases are benign masses,and 21 cases are malignant.The blood flow detection rate of PDI is higher than that of CDFI( P< 0 01).Malignant tumor is decided by the blood flow signal degree Ⅱ to Ⅲ and the benign is degree 0 to Ⅰ.PDI and CDFI are significant in statistic in deferentiating both the benign and the malignant tumors.The false negative rate of PDI is 0,and that of CDFI is 19 0%. Conclusion PDI is more detective than CDFI.It is more benefit to distinguish the benign and malignant tumors in soft tissue. [
出处 《中国医学影像技术》 CSCD 北大核心 2000年第6期479-480,共2页 Chinese Journal of Medical Imaging Technology
关键词 软组织实性肿块 能量多普勒显像 彩色多普勒显像 Solid masses in soft tissue Doppler power imaging Color Doppler flow imaging
  • 相关文献

参考文献2

二级参考文献1

共引文献57

同被引文献4

引证文献4

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部