摘要
本文对连续拉丝过程中出现铜线表面“打火现象”的原因进行分析 ,并提出简单的消除方法。
The causes for the initiation of the “spark phenomenon” during continuous wire drawing and annealing are traced. Simple measures to extinguish the spark are proposed.
出处
《电线电缆》
2000年第4期47-48,共2页
Wire & Cable
关键词
裸铜线
连续拉丝
退火工艺
打火现象
铜单线
bare copper conductor
continuous wire drawing
annealing process
quality
spark phenomenon
cause
measures