摘要
医疗电子设备接地系统的设计问题,一直备受关注。文章结合济南市历下区人民医院综合楼医疗电子设备接地系统的设计,阐述了医疗电子设备接地、等电位联结形式的选择及做法,并对在设备安装和使用过程中容易出现的问题进行了分析。
By combining Lixia District, Jinan City, People's Hospital, Comprehensive Building of medical electronic equipment grounding system design, briefly addressed the Medical electronic equipment grounding, equipotential bonding the choice of form and practices, as well as the equipment easy to install and use the process to do an analysis of the problems.
出处
《中国医院建筑与装备》
2012年第10期81-84,共4页
Chinese Hospital Architecture & Equipment
关键词
医疗电子设备
共用接地
单独接地
等电位联结
接地电阻
Medical electronic equipmentCommon ground Individual GroundEquipotential Bonding Grounding resistance