期刊文献+

Flow Injection Chemiluminescence Determination of 4-methylsalicylic

Flow Injection Chemiluminescence Determination of 4-methylsalicylic
下载PDF
导出
摘要 As potassium bichromate can be reduced by 4-methysalicylic acid to chromium(III) which enhance the CL intensity of luminol-H2O2 system,a new chemiluminescence system for the determination of 4-methysalicylic acid has been established.The relative CL intensity was correlated with salicylic acid concentration in the range 7.0×10-9~8.0×10-6 mol/L,and the detection limit was 1.0×10-9 mol/L.The relative standard deviation(n=8) for 4.0×10-7 mol/L 4-methysalicylic acid is 2.9%.The method has been applied to the determination of 4-methysalicylic acid in the bactericidal solutions with satisfactory results. As potassium bichromate can be reduced by 4-methysalicylic acid to chromium(Ⅲ) which enhance the CL intensity of luminol-H2O2 system,a new chemiluminescence system for the determination of 4-methysalicylic acid has been established.The relative CL intensity was correlated with salicylic acid concentration in the range 7.0×10-9~8.0×10-6 mol/L,and the detection limit was 1.0×10-9 mol/L.The relative standard deviation(n=8) for 4.0×10-7 mol/L 4-methysalicylic acid is 2.9%.The method has been applied to the determination of 4-methysalicylic acid in the bactericidal solutions with satisfactory results.
作者 董彦杰
出处 《陇东学院学报》 2012年第5期28-31,共4页 Journal of Longdong University
关键词 Flow injection CHEMILUMINESCENCE LUMINOL Hydrogen peroxide 4-Methysalicylic acid Flow injection Chemiluminescence Luminol Hydrogen peroxide 4-Methysalicylic acid