高阻测量仪 被引量:6

High Resistance Meter
下载PDF
导出
摘要 本文分析了影响高阻测量精度的主要因素 ,设计了以单片机为核心的高阻测量仪。采用恒流测压法和加压测流法相结合的测量方案 ,运用双屏蔽输入电缆 ,保护接地及优选输入级器件等关键技术 ,使电阻测量可达 1 0 1 6Ω ,电流测量可达 1 0 - 1 3A。 This paper mainly analyzed the affecting factor of the measurement accuracy of high resistance meter and discussed the measurement methods, which combines the voltage measurement under condition of constant current with the currant measurement under condition of the constant voltage.The instrument is based on microprocessor control. The high resistance meter adopted the input cable of two shielded layers and technique of guarded ground etc. It measures the resistance as high as 10 16 Ω and measures the current as weak as 10 -13 A.
出处 《电子测量与仪器学报》 CSCD 2000年第3期60-63,共4页 Journal of Electronic Measurement and Instrumentation
基金 国家信息产业部资助项目
关键词 高阻测量仪 加压测流仪 恒流测压法 保护接地 High resistance measurement The current measurement under condition of constant voltage The voltage measurement under condition of constant current Guarded ground
  • 相关文献

参考文献1

  • 1[1]KEITHLEY: Low Level Measurements