一种水声阵阵元相位一致性的校准方法(英文) 被引量:3

A calibration method of phase coherence between underwater acoustic array elements
下载PDF
导出
摘要 在水声领域,相位校准实际上是指水声阵阵元间的相对相位校准.绝对相位校准在实际中是没有任何的意义.相对相位的校准是指被测阵元与激励信号比较的相位差,或阵元间相位的比较.在实际使用中,阵元间相位差的测试在消声水池中一般用单频连续信号法或脉冲信号法;在非消声水池中可用脉冲信号法,在反射波影响可忽略的声场条件下,也可采用扫频连续波信号法.这些方法的共同点是对信噪比的要求比较高.借鉴了空气声的测试经验,我们把时间延时谱法应用于混响场中水声阵阵元间相位一致性的校准,解决了测试时的信噪比问题,提高测试的效率.同时,针对它无法解决非均匀声场条件下相位一致性的准确校准问题,我们引入了易地传递函数法来有效地降低声场的影响,提出了结合这两种方法特点的易地时间延时谱法用于水声阵阵元相位一致性的校准.在本文中我们从时间延时谱法和易地传递函数法的原理出发对这种方法进行了理论分析,并利用它开展了实验研究.通过对不同声场条件下利用易地时间延时谱法测量阵元位一致性与声脉冲法的比较,我们从均匀声场的实验上验证了它测量阵元相位一致性的可行性;同时,从非均匀声场的测试中证明了这种方法的优越性. The paper introduces ex-situ time delay spectrometry.It combines time delay spectrometry(TDS) and ex situ transfer function method: the use of TDS through specific tracking filter to filter out reflected signals and obtains the direct signal in order to improve the signal to noise ratio of the test.At the same time,ex situ transfer function method is used to get the geometric mean of two measurements before and after ex situ in order to reduce the error induced by the uneven sound field.The method is verified by experiments in the measurement of phase consistency between array elements and shows its effectiveness and feasibility.
作者 平自红 赵涵
出处 《南京大学学报(自然科学版)》 CAS CSCD 北大核心 2012年第5期602-608,共7页 Journal of Nanjing University(Natural Science)
关键词 水声阵阵元 传递函数 时间延时谱 相位一致性校准 phase coherence calibration array elements time delay spectrometry transfer function underwater
  • 相关文献

参考文献9

  • 1Ludwig G, Brendel K. Calibration of hydro- phones based on reciprocity and time delay spec- trometry. IEEE Transactions on Ultrasonics,Ferroelectrics, and Frequency Control, 1988, 35: 168-174.
  • 2奥本海姆AV,谢弗Rw.离散时间信号处理.西安:西安交通大学出版社,2005.
  • 3Heyser R. Acoustical measurements by time de- lay spectrometry. Journal of the Audio Engi- neering Society,1967, 15: 370-382.
  • 4Koch C H. Amplitude and phase calibration of hydrophones by heterodyne and time gated time delay spectrometry. IEEE Transactions on Ul- trasonics, Ferroelectries, and Frequency Con- trol, 2003, 50: 344-348.
  • 5Koch C h, Wilkens V. Phase calibration of hy- drophones: heterodyne time delay spectrometry and broadband pulse technique using an opticalreference hydrophone. Journal of Physics: Con- ference Series 1, 2004, 14-19.
  • 6GB/T16165-1996.水听器相位一致性测量方法,北京:中国标准出版社,1996.
  • 7Green T J, Pedersen P C, Lewin P A. Evalua- tion of time and frequency domain response of e- lectro-acoustic devices using a coherent swept frequency swept frequency measurement sys- tem. San Francisco: Ultrasonic Symposium Proceedings, 1985, 871-874.
  • 8Chivers R C. Time delay spectrometry for ultra- sonic transducer characterization. Journal of Physics E: Scientific Instruments, 1986- 19: 834-843.
  • 9Pedersen P, Lewin P A, Bjorno L. Application oF time delay spectrometry for calibration of ul- trasonic transducers. IEEE Transactions on Ul- trasonics, Ferroelectrics, and Frequency Con- tro1,1998, 35:185-205.