摘要
为了给微污染水源水处理提供可靠工艺参数,以白石水库水源水为研究对象,在水质监测基础上,对白石水库水质进行分析,并针对水源水质特点,进行了高锰酸钾与沸石联用处理微污染水源水实验研究。结果表明,白石水库各监测点位浊度、高锰酸盐指数、氨氮等指标不同程度超标,采用高锰酸钾预氧化、PAC+PAM混凝和沸石吸附联用能有效去除水中浊度、高锰酸盐指数和氨氮,使处理后三种水质指标达到生活饮用水卫生标准。
This paper aims to provide reliable technological parameters for the treatment of micro-pol- luted source water. The paper builds on the water from Baishi reservoir as research object and describes an analysis of the water quality based on water quality monitoring and experimental research on treating micro-polluted source water by combining potassium with permanganate-zeolite, as determined by water quality characteristics. The result shows that an effective removal of turbidity, permanganate, and ammonia nitrogen index found exceeding standards to varying degrees by combined adoption of preoxidation by potassium permanganate, coagulation with PAC and PAM , and zeolite adsorption leaves water qualities after treatment up to Standards for Drinking Water Quality.
出处
《黑龙江科技学院学报》
CAS
2012年第5期493-496,520,共5页
Journal of Heilongjiang Institute of Science and Technology
基金
国家大学生创新性实验计划项目(101014729)
辽宁省教育厅科学技术研究项目(L2011045)
辽宁工程技术大学科学研究立项计划项目(2010ZR15)
关键词
微污染水源水
高锰酸钾
混凝
沸石
有机物
氨氮
micro-polluted source water
potassium permanganate
coagulation
zeolite
organiccompounds
ammonia nitrogen