管球旋转时间对Volume Shuttle成像技术中成像质量及辐射剂量的影响

Influence of rotation time on radiation and imaging quality for volume shuttle technique
下载PDF
导出
摘要 目的:GE公司推出的Lightspeed VCT机型配置有Volume Shuttle技术,可以在不增加现有探测器排数的前提下扩展Z轴扫描范围,提高灌注和血管CT成像大扫描区域的时间分辨率。但是由于不断的重复扫描,X射线辐射剂量较大。本文就是否可以通过调整管球旋转时间对Volume Shuttle技术成像质量及辐射剂量进行优化的角度进行研讨。方法:实验体模采用美国Salem公司生产的Catphan 500 CT质控体模测量物理成像参数,评价图像质量。剂量参数选取CT容积剂量指数(CTDIvol)进行定量分析。结果:对于不同的材料,管球旋转时间对CT值准确性的影响不具有同一性。较长的旋转时间可以降低噪声,提高图像对比度噪声比(CNR),但细节分辨力无变化。根据剂量归一化后图像CNR显示,较短的管球旋转时间更具有优势。结论:从单位辐射剂量对图像CNR的贡献角度而言,相对短的管球旋转时间的效率更高。有望寻求到管球旋转时间和图像质量的最佳匹配点,实现Volume Shuttle技术的辐射剂量优化。 Objective: Volume Shuttle technique, proposed on GE Lightspeed VCT, expends z-scanning area without the limitation of detector width. Therefore, this technique made CT perfusion and angiography for large area with good temporal resolution. However, non-stop shuttle increases radiation dose. The purpose of the present study was to verify whether it is possible to adjust rotation time to optimize radiation without deteriorating image quality.Methods: Catphan 500 CT quality control phantom was used to obtain physical metrics of CT imaging and to evaluate imaging. CTDIvol was selected to be radiation parameter. Results: For different materials, rotation time affected the accuracy of CT number in different ways. Longer rotation time decreased average noise and increased CNR, without changing detail resolution. However, according to the normalized CNR to radiation, shorter rotation time was more effective to the CNR of imaging. Conclusion: As for the contribution of normalized radiation to imaging CNR, shorter rotation time was more efficient. It was potential to adjust rotation time to match the golden combining of radiation and imaging quality in order to optimize volume shuttle techniques.
出处 《中国医学装备》 2012年第10期4-7,共4页 China Medical Equipment
基金 国家自然科学基金(30870751)"多排螺旋CT临床成像质量与受检者受照剂量优化匹配及评价方法研究"
关键词 计算机断层成像 管球旋转时间 辐射剂量 成像质量 Computed tomography Influence of rotation time Radiation dose Image quality
  • 相关文献

参考文献15

  • 1Hsiao EM, Rybicki F J, Steigner M. CT coronary angiography..256-slice and 320-detector row scanners[J]. Curr Cardiol Rep,2010,12(1):68-75.
  • 2Choi SI, George RT, Schuleri KH, et al.Recent developments in wide-detector cardiac computed tomography[J].Int J Cardiovasc Imaging, 2009,25(Suppl 1): 23-29.
  • 3Khan A, Khosa F,Nasir K,et al.Comparison of radiation dose and image quality: 320-MDCT versus 64-MDCT coronary angiography[J].AJR Am J Roentgenol,2011,197(1). 163-168.
  • 4Endo M,Mori S, Tsunoo T, et al. Magnitude and effects of x-ray scatter in a 256-slice CT scanner[J]. Meal Phys, 2006,33(9): 3359-3368.
  • 5Perisinakis K, Papadakis AE, Damilakis J.The effect of x-ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging[J]. Med Phys, 2009,36(4) :1258-1266.
  • 6Mieville FA, Gudinchet F, Brunelle F, et al. Iterative reconstruction methods in two different MDCT w_anners: Physical metrics and 4-alternative forced-choice detectability expeliments-A phantom approach[J].Phys Med,2012,2[Epub ahead of print].
  • 7Brisse H J, Brenot J, Pierrat N, et a].The relevance of image quality indices for dose optimization in abdominal multi-detector row CT in children: expemnental assessment with pediatric phantoms[J]. Phys Med Biol, 2009,54(7): 1871-1892.
  • 8白玫,彭明辰.X线CT成像质量评估中的调制传递函数的测试与分析[J].医疗设备信息,2006,21(5):11-13. 被引量:15
  • 9Ay MR,Mehranian A,Maleki A, et al.Experimental assessment of the influence of beam hardening filters on image quality and patient dose in volumetric 64-slice X-ray CT scanners[J].Phys Med,2012,25[Epub ahead of print].
  • 10Yveborg M,Danielsson M,Bornefalk H,et al.Performance evaluation of a sub-millimetre spectrany resolved CT system on high- and low- frequency imaging tasks: a simulation[J].Phys Med Biol,2012,57(8)..2373 2391.

二级参考文献15

  • 1刘秀珍.X-CT辐射剂量的测量[J].医疗卫生装备,2006,27(2):61-62. 被引量:5
  • 2白玫.浅谈螺旋CT辐射剂量的测量[J].医疗设备信息,2006,21(7):33-35. 被引量:5
  • 3[2]GB 18871-2002,电离辐射防护与辐射源安全基本标准[S].
  • 4[1]United States Food and Drug Administration Center for Devices and Radiological Health.Whole boay scanning:using computed tomography(CT)[S/OL].Available at:http://www.fda.gov/cdrh/ct.
  • 5[2]European Guidelines on Quality Criteria for Computed Tomography[S/OL].Available at:http://www.dr s.dk/ guiddines/ct/q uality/index.htm.
  • 6[5]International Commission on Radiological Protection,Publication 60:1990 Recommendations of the International ommission on Radiological Protection[S].Annals of the ICRE Vol 21,Nos.13 (Pergamon,Oxford,1991).
  • 7[6]XU X G,CHAO T C,and BOZKURT A.VIP-Man:An image-based whole-boay adult male model constructed from color photographs of the visible human project for multi-particle[J].Monte Carlo calculafiom Health Physics,78(5)476-486,(2000).
  • 8Goodenough D,Atkins F,Dyer S.Automated techniques for quality assurance of radiological image modalities.SPIE.Image Capture,Formatting,and Display,1991,1444:87-99.
  • 9Dainty JC,Shaw R.Image Science[M].New York:Academic Press,1974.
  • 10Goodenough D,Atkins F.Theoretical and practical aspects of automated quality assurance approaches,particularly for CT[C].Proceedings of the ICR 89,editors Silve,et.Al,1990.

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部