期刊文献+

旭化成NCZ零极距电解槽应用技术研究 被引量:5

Research on operation technologies of Asahi Kasei NCZ zero-polar distance electrolyzers
下载PDF
导出
摘要 总结了旭化成NCZ零极距电解槽的使用情况及整体换膜检查中发现的问题,并进行了可能原因的分析,同时提出了该型号电解槽在日常使用控制中的注意点。 The application situation of Asahi Kasei NCZ zero-polar distance electrolyzers and the problems that were found during examination and change of all membranes.The possible causes are analyzed.The points needing attention for routine operation of the electrolyzers are proposed.
出处 《氯碱工业》 CAS 2012年第10期13-16,共4页 Chlor-Alkali Industry
关键词 零极距电解槽 离子膜法电解 存在问题 原因分析 操作要点 Zero-polar distance electrolyzer ion-exchange membrane electrolysis problem cause analysis operation point
  • 相关文献

参考文献2

共引文献7

同被引文献31

  • 1宋玉亮,常孝,王刚,王朋.离子膜法烧碱生产影响因素分析[J].氯碱工业,2006,42(7):21-22. 被引量:6
  • 2赵国瑞.高电流密度自然循环复极式离子交换膜电解槽在氯碱工业的应用[J].氯碱工业,2007,43(11):11-18. 被引量:6
  • 3Kemal Aldas. Application of a two-phase flow model for hydrogen evolution in an electrochemical cell [J]. Applied Mathematics and Computation, 2004, 154:507-519.
  • 4Mahmut D Mat, Kemal Aldas. Application of a two-phase flow model for natural convection in an electrochemical cell [J]. International Journal of Hydrogen Energy, 2005, 30:411-420.
  • 5Abbasi Farshad, Rahimzadeh Hasan. Applying a modified two-fluid model to numerical simulation of two-phase flow in the membrane chlor-alkali ceils [J]. Iranian Journal of Chemistry & Chemical Engineering-International English, 2008, 27 (3): 51-61.
  • 6ChengDianbin(程殿彬),ChenBosen(陈伯森),ShiXiaokui(施孝奎).The Production Technology of Ion-exchange MembraneCaustic Soda [M]. Beijing: Chemical Industry Press, 1998:62.
  • 7ZhangZhaoxian(张招贤).Titanium Electrode Reaction Engineering[M]. Beijing: Metallurgical Industry Press,2009:28.
  • 8WenZheng(温正),PenYiru(任毅如).FLUENT Fluid CalculationApplication Tutorial[M]. Beijin: Tsinghua University Press, 2009:12.
  • 9Fumio Hine, Koichi Murakami. Bubble effects on the solution IR drop in a vertical electrolyzer under free and forced convection [J]. Journal of The Electrochemical Society, 1980, 127 (2): 292-297.
  • 10Asahi Kasei Corporation. Double pole zero distance between electrolytic cell [P]: JP, CN1717507.2006-01-04.

引证文献5

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部