2Linzer M, Pritchett ELC, Pontinen M, et al. Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope. Am J Cardiol, 1990,66:214-219.
3Thijssen J, Borleffs CJ,van Rees JB,et al. Implantable cardioverter-defibrillator longevity under clinical circumstances ? an analysis according to device type,generation,and manufacturer. Heart Rhythm,2012, 9:513-519.
5Krahn AD,Klein GY,Yee R,et al. Randomised Assessment of Syncope Tried; conventional diagnostic testing versus a prolonged monitoring strategy. Circulation,2001,104;46-51.
6Farwell DJ,Sulke AN. A randomised prospective comparison of three protocols for head-up tilt testing and carotid sinus massage. Int J Cardiol ,2005,105:241 -249.
7Parry SW, Matthews IG. Implantable loop recorders in the investigation of unexplained syncope: a state of the art review. Heart, 2010,96; 1611-1616.
8Menoza C,Brignole M,Garcia-Civera R,et al. Mechanism of syncope in patients with heart disease and negative electrophysiological test. Circulation ,2002,105:2741 -2745.
9Brignole M,Moya A,Menozzi C,et al. Proposed electrocardiographic classification of spontaneous syncope documented by an implantable loop recorder. Europace,2005,7:19-24.
10Moya A, Sutton R,Ammirati F,et al. Guidelines on diagnosis and management of syncopedversion 2009. Eur Heart J,2009,30:2631-2671.
2Maisel WH. Pacemaker and ICD Generator Reliability Meta-analysis of Device Registries. JAMA ,2006,295:1929-1934.
3Ribeiro AL, Rincon LG, Oliveira BG, et al. Enhancing longevity of pacemakers through reprogramming. Underutilization and cost-effectiveness. Arq Bras Cardiol,2001,76 :437-444.
4Boriani G, Rusconi. Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: a prospective study Europace ,2006,8 ( 3 ) :216-220.
5Maisel WH, Moynahan M, Zuckerman BD, et al. Pacemaker and ICD generator malfunctions : analysis of Food and Drug Administration annum reports. JAMA ,2006,295 : 1901-1906.
6Aydemir O, Ozmen E, Ktiey L, et al. Psychiatric morbidity and depressive symptomatology in patients with permanent pacemakers. PACE, 1997,20 : 1628-1832.
7Kapa S, Hyberger L, Rea RF, et al. Complication risk with pulse gererator change:implications when reacting to a device advisory or recall. PACE ,2007,30:730-733.
8Costea A, Rardon DP, Padanilam B J, et al. Complications associated with generator replacement in response to device advisories. J Cadiovasc Electrophysiol,2008 ,19 :266-269.
9BoreK PP, Wikoff BL. Pacemaker and ICD leads:strategies for long- term management. J Interv Card Eleetrophysiol,2008 ,23 :59-72.
10Catanchin A, Murdock C J, Athan E. Pacemaker infection : a 10-year experience. Heart Lung Circ ,2007,16:434-439.