期刊文献+

金属氧化物避雷器用脱离器的关键技术研究及标准制定的建议 被引量:1

Study of Key Technologies of Disconnector Used in Metal Oxide Surge Arrester and Proposals for Standard
原文传递
导出
摘要 脱离器可以将故障避雷器隔离出运行系统,并给出明显、永久的脱离标示,是金属氧化物避雷器的主要附件之一。IEC60099-4、GB11032等避雷器标准规定了脱离器的技术要求和试验方法。但是,在实际运行中脱离器出现不少质量问题,严重影响到电网的安全。我们在脱离器工作原理的基础上,对其关键技术进行了较深入的研究,建议尽快制定金属氧化物避雷器用脱离器的行业标准。 A disconnector can disconnect an arrester from the system in the event of arrester failure and give visible and permanent indication of disconnection. It is one of the key accessories of metal oxide surge arresters. The technical requirements and test methods for disconnector are specified in arrester standards such as IEC60099-4, GBl1032 and etc.. However, a lot of quality problems have arisen in actual operation, which seriously affected the safety of the grid. The key technologies of disconnector are further researched based on its operation principle. It is recommended to develop an industry standard of the disconnector used in metal oxide surge arresters as soon as possible.
出处 《电瓷避雷器》 CAS 北大核心 2012年第5期64-69,73,共7页 Insulators and Surge Arresters
关键词 脱离器 避雷器 标准 disconnector surge arrester standard
  • 相关文献

参考文献19

二级参考文献15

  • 1DL/T620-1997交流电气装置的过电压保护和绝缘配合[S].
  • 2GB31 1.1—97.高压输变电设备绝缘配合[S].[S].,..
  • 3GB11032—2000.交流无间隙金属氧化物避雷器[S].[S].,..
  • 4JB/T8952—1999.35kV及以下交流系统用复合外套无间隙金属氧化物避雷器[S].[S].,..
  • 5DL/T620—1997.交流电器的过电压保护和绝缘配合[S].[S].,..
  • 6张仁豫.高压绝缘[M].北京:清华大学出版社,1982..
  • 7国家绝缘子避雷器质量监督检测中心.110kV-200kV带串联间隙线路避雷器试验报告[R].西安:西安电瓷研究所,2003..
  • 8JB/T×××-××××.交流输电线路用有串联间隙复合外套金属氧化物避雷器[S].[S].,..
  • 9IEC60099-4 (2001), Metal-oxide surge arresters without gaps for a. c. systems[S] .
  • 10IEEE C62. 11-1999, IEEE Stands for metal-oxide surge areesters for AC power circuits (>1kV) [S] .

共引文献76

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部