摘要 绝缘子人工污秽闪络试验3种常用的电气试验方法,包括均匀升压法、50%耐受电压法和最大耐受电压法。目前,国内外对试验方法影响绝缘子直流污闪特性的研究很少,该文基于人工气候室内7片染污瓷和玻璃绝缘子串(XP-160、XWP2-160、LXY4-160、LXHY3-160)直流闪络特征的测量,比较了3种电气试验方法下绝缘子串的直流污闪电压的差异。结果表明:试验方法对绝缘子的直流污闪电压有影响;对于相同类型的绝缘子,直流闪络电压与等值附盐密度(ESDD)拟合公式均满足负幂指数函数关系,与使用的电气试验方法无关。因此,可以根据试验的具体情况,选择适当的试验方法。 There are three electrical testing methods frequently used, including average flashover voltage method, 50% withstand voltage method and maximum withstand voltage method in the insulator artificial pollution fiashover tests. At present, there is little research on DC pollution flashover characteristics of insulators among these methods at the home and abroad. Based on measurements of DC flashover characteristics of contaminated porcelain, glass insulator strings of 7 units (XP-160, XWP2-160, LXY4-160, LXHY3-160) in the artificial climate chamber, the differences on the DC flashover voltage of insulator strings were compared under three electrical testing methods in this paper. The tests show that there are some differences on the pollution flashover voltages using different methods. Moreover, the fitting formulas, which are simulated on DC flashover voltages at the various equivalent salt deposit densities (ESDD) for the same type of insulator, are consistent with various evaluation methods. So, the appropriate testing method can be selected according to the specific testing circumstances.
出处 《中国电机工程学报》 EI CSCD 北大核心 2012年第31期122-127,227,共6页 Proceedings of the CSEE
基金 国家重点基础研究发展计划项目(973计划)(2009CB724501/502/503) 国家创新研究群体基金(51021005)~~
关键词 污秽试验 人工污秽 绝缘子 电气试验方法 流污闪特性 pollution test artificial pollution insulator electrical testing method DC flashover performance
  • 相关文献

参考文献17

  • 1张志劲,蒋兴良,孙才新.污秽绝缘子闪络特性研究现状及展望[J].电网技术,2006,30(2):35-40. 被引量:137
  • 2Jiang X,Yuan J,Zhang Z, et al. Study on pollutionflashover performance of short samples of compositeinsulators intended for ±800 kV UHV DC[J]. IEEETransactions on Dielectrics and Electrical Insulation,2007,14(5): 1192-1200.
  • 3Ishii M,Komatsubara M,Matsuoka R. Behavior ofinsoluble materials in artificial contamination tests[J]. IEEE Transactions on Dielectrics and ElectricalInsulation, 1996, 3(3): 432-438.
  • 4宿志一 刘燕生.线路污秽绝缘子的直流雾中耐受电压特性.高电压技术,1986,12(3):20-24.
  • 5Ely C H A, Kingston R G,Lambeth P J. Artificial andnatural pollution tests on outdoor 400 kV substationinsulators [J]. Proceedings of the Institution of ElectricalEngineers, 1971,118(3): 99-108.
  • 6李立浧,蒋兴良,孙才新,张志劲,胡建林.±800kV直流复合绝缘子短样人工污秽闪络特性研究[J].中国电机工程学报,2007,27(10):14-19. 被引量:34
  • 7Matsuoka R,Kondo K,Naito K,et al. Influence ofnonsoluble contaminants on the flashover voltages ofartificially contaminated insulators[J]. IEEE Transactionson Power Delivery,1996,11(1): 420-430.
  • 8Lambeth P J. Variable voltage application for insulatorpollution tests [J]. IEEE Transactions on Power Delivery,1988, 3(4): 2103-2111.
  • 9张鑫,蒋兴良,张志劲,胡建林,肖代波.试验方式对瓷和玻璃绝缘子交流污闪特性的影响[J].高电压技术,2009,35(11):2674-2679. 被引量:5
  • 10蒋兴良,肖代波,胡建林,张志劲,张鑫.试验方法对复合绝缘子污秽闪络特性的影响[J].高压电器,2010,46(2):8-11. 被引量:16