期刊文献+

自制外固定器固定股骨转子间骨折的生物力学研究 被引量:3

Biomechanical Study of Self-designed External Fixation for Inter-trochanteric Fracture
下载PDF
导出
摘要 目的通过生物力学实验研究对自制外固定器固定股骨转子间骨折的生物力学性能进行评价。方法取15具成人甲醛固定股骨标本,造成AO分型31-A1.1型转子间骨折模型。试验组用自制外固定器固定,对照组用单侧成角外固定器固定和动力髋螺钉固定。实验分为骨折端相当接触面积、极限承载能力等方面。结果试验组的骨折端相当接触面积以及极限承载能力均明显大于动力髋螺钉和单侧成角外固定支架(P<0.05)。结论自制外固定架的相当接触面积、极限力学性能明显大于动力髋螺钉和单侧成角外固定器,固定可靠,能避免或减少髋内翻等并发症。 Objective To evaluate biomechanical properties of the self-designed external fixation(SDEF) for inter-trochanteric fracture.Methods Fifteen adult femur specimens were fixed by formaldehyd,and the models of 31-A1.1(AO classification) fracture were established.For the experimental group the specimens were fixed with the self-designed external fixation(5 specimens) The control group were respectively fixed with dynamic hip screw(DHS)(5 specimens) and unilateral angulated external fixator(UAEF)(5 specimens).Contact area in the broken ends of fracture and maximum endurance were tested.Results The contact area in the broken ends of fracture and the maximum endurance of the experimental group were superior to dynamic hip screw and the traditional one arm external fixator(P0.05).Conclusion The contact area in the broken ends of fracture and the maximum endurance of the experimental group are superior to dynamic hip screw and the unilateral angulated external fixator.
出处 《实用骨科杂志》 2012年第10期904-908,共5页 Journal of Practical Orthopaedics
关键词 转子间骨折 外固定架 生物力学 intertrochanteric fractur external fixator biomechanical
  • 相关文献

参考文献6

二级参考文献28

共引文献176

同被引文献38

  • 1徐生根,王驰,徐正发,周杨礼,毛兆光.动力髁螺钉治疗股骨粗隆间骨折生物力学的研究[J].浙江中医药大学学报,2007,31(1):67-68. 被引量:9
  • 2King AI.A review of biomechanical models[J]J Biomech Eng, 1984,106(2):97-104.
  • 3Blemker SS,AsakawaDS’Gold GE,et al.Image-basedmusculoskele-tal modeling:applications,advances,and future opportunities[J].JMagn Reson Imaging, 2007,25(2):441-451.
  • 4Chen C Y,Chiu F Y,Chen C M,et al. Surgicat treatment of basi-cervical fractures of femur-A prospective evaluation of 269patients [J]. J Trauma,2008,64(2) : 427-429.
  • 5Mereddy P, Kamath S,Ramakrishnan M,et al .the AO / ASIF pr-oximal fermoral nail antirotation (PFNA): a new design for thetreatment of unstable proximal femoral fracturea[J]. Injury, 2009,40(4) :428.432.
  • 6Kouvidis GK,Sommers MB,Giannoudis PV,et al.Comparison of mi-gration behavior between single and dual lag screw implants forintertrochanteric fracture fixation. J Orthop Surg Res,2009,4:16.
  • 7Gadegone WM,Salphale YS.Proximal femoral nail-an analysis of100 cases of proximal femoral fractures with an average follow upof 1 year. Int Orthop,2007,31 ( 3) :403-408.
  • 8Engin Eceviz,Korhan Ozkan , Koray Unay,et ai.Distal unlockedoximal femoral intramedullary nailing for intertrochanteric femurfractures.Int Orthop,2008,33 (5):1397-1400.
  • 9Lei Liu,Yue Fang,Tian-Fu Yang,et al.Results of the proximal fe-moral nail anti-rotation (PFNA) in elderly Chinese patients.IntOrthop,2009,33(5):1441-1444.
  • 10Jewell DP,Gheduzzi S,Mithchell MS,et a 1. Locking plates inc-rease the strength of dynamic hip screws[J]. Injury,2008,39(2):209.212.

引证文献3