摘要
分析了某电厂1#机组A空预器运行中发生卡涩故障的原因,总结了机组高负荷情况下将故障空预器单侧隔离以及处理的过程,得出合理的处理策略,确保了机组安全、稳定运行.
The cause of the jamming failure taking place in the unilateral air preheater during high load operation in Unit 1 of a certain power plant is analyzed. The treating processes on the air unilateral isolation of preheater during high load operation are summarized, which helps to ensure the stable operation of the unit.
出处
《上海电力学院学报》
CAS
2012年第5期448-450,456,共4页
Journal of Shanghai University of Electric Power
关键词
锅炉
空预器
卡涩故障
boiler
air preheater
jamming failure