翅片管换热器流程布置对换热性能影响的实验研究 被引量:2

Experimental Study of the Effect of Circuit Arrangement on the Heat Exchange Performance of Fin-tube Heat Exchanger
下载PDF
导出
摘要 在分析翅片管换热器流程布局对换热器换热性能影响的基础上,通过实验对两种不同流程布局在制冷和制热工况下进行性能对比,分析制冷和制热循环下流程布局的差异和换热器性能提高的原因。同时对改良后的流程布局进行利弊分析,对企业选择流程布置具有参考意义。 Based on theoretical analysis of the effect of circuit arrangement on the heat exchange performance,two kinds of circuit arrangements were tested under the cooling and heating conditions through experiment.The heat exchange performance,differences of the two circuit arrangements and the reasons of performance improvement were analyzed.At the same time,the advantages and disadvantages of the improved circuit arrangement were pointed out.Those can give references for enterprises in selecting circuit arrangements.
作者 王艳 廖玉松
出处 《现代机械》 2012年第5期38-40,共3页 Modern Machinery
基金 2011年安徽省省级质量工程项目--省级特色专业建设阶段性成果之一(皖教高[2011]5号文件第121项)
关键词 翅片管换热器 能效比 流程布局 换热性能 fin-tube heat exchanger energy efficiency ratio circuit arrangement heat exchange performance
  • 相关文献

参考文献4

二级参考文献26

  • 1刘建,魏文建,丁国良,王凯建.对具有复杂流路布置的翅片管换热器的性能仿真与分析[J].化工学报,2005,56(1):47-52. 被引量:24
  • 2郑钢.使用R407C冷媒的翅片管冷凝器的计算机模拟[J].建筑热能通风空调,2005,24(1):18-21. 被引量:1
  • 3邓斌,徐百平,林澜.R22替代工质蒸发器的性能研究[J].低温与特气,2005,23(2):15-19. 被引量:1
  • 4杨世铭.传热学(第2版)[M].北京:高等教育出版社,1987,10..
  • 5Webb R L. Principle of enhanced heat transfer. John Wiley & Sons, Inc, New York, 1994
  • 6Wanb C C, Jang J Y, Lai CC, et al. Effect of circuit arrangement on the performance of air-coold condensers. Int J Refrig, 1999, 22(4):275-282
  • 7Schlager L M,Pate M B, Bergles A E. Heat transfer and pressure drop during evaporation and condensation of R22 in horizontal micro-fin tubes. Int J Refrig, 1989, 12(1):6-14
  • 8Liu X. Condensing and evaporating heat transfer and pressure drop characteristics of HFC134a and HCFC22. J Heat Transfer, Transaction of ASME, 1997,119(1):158-163
  • 9Aganda A A,Coney J E R,Sheppard C G W.Airflow maldistribution and the performance of a packaged air conditioning unit evaporator.Applied Thermal Engineering,2000,20(6):515-528.
  • 10Amgad.Effect of airflow maldistribution on pressure drop and thermal performance of heat exchangers in residential heat pump systems.ASHRAE Transaction,2003,109(1):9-14.

共引文献43

同被引文献29

  • 1邓斌,廖清高,林澜,陶文铨.流程布置对R410A冷凝器性能的影响研究[J].制冷技术,2006,26(2):8-12. 被引量:7
  • 2邓斌,陶文铨,林澜.冷凝器流程布置的数值模拟研究(2):计算结果与分析[J].暖通空调,2006,36(10):51-55. 被引量:3
  • 3邓斌,陶文铨,林澜.流程布置对R407C冷凝器性能的影响[J].制冷,2006,25(4):57-62. 被引量:1
  • 4龚建英,袁秀玲,黄东,张兴群.不均风速场对中大型热泵结霜工况性能的影响[J].西安交通大学学报,2007,41(9):1058-1061. 被引量:3
  • 5臧润清.利用热虹吸实现蒸发器超倍供液的制冷系统.流体工程,1988,(3):58-61.
  • 6Ellison P R, Crewick F A, Fischer F K, Jackson W L.A computer model for air- cooled refrigerant condenser with specified refrigerant circuiting[J]. ASHRAE Transaction, 1981,4:1106-1124.
  • 7Wang C C, Jiang J Y, Lai C C, et al. Effect of circuit arrangement on the performance of air cooled condensers. International Journal of Refrigeration, 1999, 22(6):275-282.
  • 8S Y liang, T N Wong, G K Nathan. Study on refrigerant circuitry of condenser coils with exergy destruction. Applied Thermal Engineering, 2000, 20(6): 559-577.
  • 9J H Lee, S W Bae, K H Bang, et al. Experimental and numerical research on condenser performance for R22 and R407C refrigerants. International Journal of Refrigeration, 2002, 25(3):372-382.
  • 10Jian liu, Wen Jian Wei, et al. A general steady state mathematical model for fin-and-tube heat exchanger based on graph theory. International Journal of Refrigeration, 2004,27(8): 965-973.

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部