在分析翅片管换热器流程布局对换热器换热性能影响的基础上,通过实验对两种不同流程布局在制冷和制热工况下进行性能对比,分析制冷和制热循环下流程布局的差异和换热器性能提高的原因。同时对改良后的流程布局进行利弊分析,对企业选择流程布置具有参考意义。
Based on theoretical analysis of the effect of circuit arrangement on the heat exchange performance,two kinds of circuit arrangements were tested under the cooling and heating conditions through experiment.The heat exchange performance,differences of the two circuit arrangements and the reasons of performance improvement were analyzed.At the same time,the advantages and disadvantages of the improved circuit arrangement were pointed out.Those can give references for enterprises in selecting circuit arrangements.
出处
《现代机械》
2012年第5期38-40,共3页
Modern Machinery
基金
2011年安徽省省级质量工程项目--省级特色专业建设阶段性成果之一(皖教高[2011]5号文件第121项)
关键词
翅片管换热器
能效比
流程布局
换热性能
fin-tube heat exchanger
energy efficiency ratio
circuit arrangement