摘要 以山西兴能发电有限责任公司二期2×600 MW直接空冷机组为例,分析了凝结水精处理混床运行周期短、制水量少、树脂再生频繁的问题,从混床进水水质、再生剂纯度、给水加氨量及失效树脂的输送等方面查找原因,提出了相应的改进措施。实践证明,改进效果明显。 Some problems,such as the short operation cycle,the small amount of the prepared water,the frequent regeneration of the resin and others,existed in the mixed bed for condensed water fine treatment of the 2×600 MW direct air cooled unit of the Shanxi Xingneng Power Generation Company Limited project phase II.The reasons of the problems were found from several aspects,which include the quality of the mixed bed input water,the purity of the regenerating agent,the amount of the ammonia added into the feed water and the conveying of the exhausted resin.The improvement measures were proposed,and the practice shows that the effects of the measures are favorable.
出处 《华电技术》 CAS 2012年第10期52-54,79,共3页 HUADIAN TECHNOLOGY
关键词 凝结水 精处理 混床 制水量 运行周期 condensed water fine treatment mixed bed amount of prepared water operation cycle
  • 相关文献

参考文献8

二级参考文献29

  • 1沈伯雄,孙幸福.天然气先进再燃区脱硝效率影响因素的实验与模拟研究[J].中国电机工程学报,2005,25(5):146-149. 被引量:32
  • 2孙克勤,周长城,徐海涛.火电厂烟气脱硝技术及其设备国产化建议[J].冶金环境保护,2005(3):30-32. 被引量:1
  • 3赵振宙,金保升,熊源泉,孙克勤.锅炉“内爆”的动态模拟和预测[J].热能动力工程,2007,22(2):163-167. 被引量:4
  • 4Determination Of Sulfuric Acid and Sulfur Dioxide Emissions From Stationary Sources[S]. EPA-method 8.
  • 5Determination Of Sulfur Oxides Emissions From Stationary Sources[S]. EPA-method 6.
  • 6北京国电科环洁净燃烧工程技术有限公司.妈湾#1锅炉炉内动力场、温度场及燃尽风部分数值模拟报告[R].北京:北京国电科环洁净燃烧工程技术有限公司,2008.
  • 7烟台龙源电力技术股份有限公司.深圳妈湾电力有限公司1号锅炉燃烧器低NOx改造设计说明[R].北京:烟台龙源电力技术股份有限公司,2008.
  • 8西安热工研究院有限公司.深圳妈湾电力有限公司一号锅炉大修后试验报告[R].西安:西安热工研究院有限公司,2009.
  • 9中国环境科学研究院环境标准研究所.火电厂氮氧化物防治技术政策(征求意见稿)编制说明[M].北京:中国环境科学研究院环境标准研究所,2009.
  • 10郭斌.火电厂氮氧化物控制策略的研究报告[R].广州:广东电网公司电力科学研究院,2009.

共引文献131

同被引文献38

引证文献6

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部