摘要
本文介绍了厦门市工人文化宫地下停车场内长距离消防卷帘降温保护问题的方案比较 ,认为类似工点应当优先采用加密喷头闭式自动喷水系统。并且侧重表达了加密喷头闭式自动喷水系统设计中的一些见解和处理方式。
The comparison of schemes for lowering temperature protective problem of the long distance fireproof rolling curtain in the underground car park of Xiamen Workers' Cultural Palace is introduced. It was considered that the close type automatic water spraying system with densely arranged spray nozzles should be used priorly for the similar engineering project. Several opinions and treatment mode for the design of this system are demonstrated emphatically also in this paper.
出处
《铁道工程学报》
EI
2000年第3期109-111,共3页
Journal of Railway Engineering Society
关键词
加密喷头
自动喷水系统
防火卷帘
地下停车场
densely arranged spray nozzles
automatic water spraying system
water screen system
fireproof rolling curtain