期刊文献+

不同材料固定寰枢椎脱位在屈伸状态下有限元分析

Three-dimensional Finite Element Analysis of Magnesium Alloy and Titanium Alloy TARP System in the Treatment of Atlantoaxial Dislocation:A Comparison of Anti-torsion Properties,
下载PDF
导出
摘要 目的:对前路寰枢椎脱位的患者,应用三维有限元分析法对镁合金与钛合金材料TARP钢板固定,进行屈状态下对比分析,为临床提供理论依据。方法:选择一例寰枢椎脱位患者,进行CT扫描和三维重建,将数据导入有限元分析软件,对结果进行统计学分析。结果:表明上颈椎的有限元模型外形逼真,几何相似性好,共包含67846个节点,225368个单元,应力集中区域为关节应力集中区域分别为颈1/2关节突关节,在模拟前屈时,寰枢椎在颈1/2关节突关节应力比较集中,其次是齿状突基底部。镁合金和钛合金固定材料有显著性差异(P<0.05)。结论:应用CT扫描获取上颈椎空间结构信息建立的上颈椎模型可用于生物力学实验,镁合金材料比钛合金材料临床固定效果更好,值得在临床进一步推广应用。 Abstract Objective: To discuss the apphcation different of materials transoralpharyngeal atlantoaxial reduction plate (TARP) in the treatment of unreducible atlantoaxial dislocation by using finite element analysis methods, and to provide theoretical support for its clinical application. Methods: A typical example of atlantoaxial fracture dislocation patients, and CT thin titanium alloy and the clinical application of TARP system scanl and access to DICOM image data, import three-dimensional finite element analysis software, were simulated using the two kinds of titanium and magnesium alloydifferent materials preparation TARP reduction and internal fixation, Results: The results were statistically analyzed. Built in the shape of atlantoaxial dislocation reduction and internal fixation of the finite element model realistic, geometric similarity, a total of 67846 nodes, 225368 units; in the simulated head is located immediately, the stress concentration region were neck1/2 of the facet joints, followed by the fascia dentate basement ; the two different materials of magnesium alloy and titanium alloy preparation of TARP system, the distribution of the corresponding mechanical there are significant differences (P〈0.05). Conclusion: CT scan was established to obtain structural information in atlantoaxial model can be used for biomechanical experiments; The use of existing titanium TARP treatment of atlantoaxial dislocation, and maintain the anterior arch of arias, arch is complete, and fusion of the lateral mass indeed, you can better maintain the stability of ariantoaxial; atlantoaxial fusion, the facet joints of adjacent segments increased the force to accelerate the degeneration, should be closely followed up; The magnesium alloy materials for preparation of the TARP system better than titanium TARP in the stress concentration region lower and peak stress distribution improved, needs further study.
出处 《中国数字医学》 2012年第10期44-47,共4页 China Digital Medicine
基金 全军医学科研"十二五"重点项目(编号:bws11c065) 全军医学科研"十二五"面上项目(编号:cws11c268) 广东省骨科矫形技术与植入材料重点实验室(编号:[2011]233-32) 广东省科技计划项目(编号:2010B10800006) 广州市科技计划项目(编号:2010J-E311)~~
关键词 上颈椎 寰枢椎 脱位 有限元分析 Department of Orthopadedics, Guangzhou General Hospital of PLA, Guangzhou 510010, GuangdongProvince, P.R.C.
  • 相关文献

参考文献12

二级参考文献55

共引文献107

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部